ELECTRICAL INSTALLATION
50
IPA Hardware Installation Guide
Brake Relay to Motors with Full Wave Rectifiers
Newer Parker brake motors contain full wave rectifiers, so connection polarity is not an issue during installation.
Older motors (BE, SM, NeoMetric, and J series motors, serial numbers less than 010904xxxxx) do not have
rectifiers. SMN motors less than 050801xxxxx do not have rectifiers. MPM motors do not have rectifiers.
Brake Relay does not supply 24VDC. Use an external source. Recommend that this supply is separate from supply
for logic to prevent noise on digital I/O.
1
Connect one red/blue brake wire (Parker Motor cable or equivalent) to one BK terminal.
2
Connect the second red/blue brake wire (Parker Motor cable or equivalent) to the 24V return on the
power supply.
3
Connect the +24 VDC power supply to the second BK terminal.
The following figure shows a typical application.
Figure 18. -
Brake Relay Connection for Motor with Full Wave Rectifiers
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...