All drive/controller communications are based on Ethernet. The IPA may be connected directly to any
appropriately configured Ethernet port. The drive IP address will be 192.168.100.xx, where xx is defined by the
address selection switches on the unit’s front panel.
RJ-45 Ethernet Status LEDs
The first step in troubleshooting communications is to observe the state of the RJ-45 Ethernet Status LEDs. (Figure
30 shows their location on the drive’s dual-stack RJ-45 socket.) These LEDs indicate any Ethernet connection, as
described in the next table. Note that for a standard 100Mbps connection, both the yellow and green LED should
be illuminated. For a 10Mbps Ethernet connection, the Yellow LED should be illuminated and the Green LED off.
Figure 30. -
RJ-45 Ethernet Status LEDs
Ethernet Status LED Descriptions
LED
Steady Flash
Description
Ethernet
Link/Activity
Off
Yellow
—
—
No Ethernet link detected
Ethernet link established,
no activity
—
Yellow
Ethernet link established
and active
Ethernet Speed
Off
Ethernet 10Mbps
Green
Ethernet 100Mbps
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...