ELECTRICAL INSTALLATION
IPA Hardware Installation Guide
51
Brake Relay to Motors without Full Wave Rectifiers
When using Parker MaxPlus motors, Parker motors with serial numbers less than 010904xxxxx, or non-Parker
motors, you must install a fly-back diode. Consult the specifications or the manufacturer of your motor.
1
Connect one red/blue brake wire (Parker Motor cable or equivalent) to one BK terminal (located on the
Motor connector.
2
Connect the second red/blue brake wire (Parker Motor cable or equivalent) to the 24V return on your
power supply.
3
Between the two red/blue wires, connect the fly-back diode.
4
Connect the +24 VDC power supply to the second BK terminal.
The following figure shows a typical installation.
Figure 19. -
Brake Relay Connection for Motor without Full Wave Rectifiers
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...