FL20-S Series
261
So-37
Motor overload coefficient setting
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
1
~
500
%
100
Effective Immediate
Please refer to 6.6.2 for details.
So-38
Under voltage protection of LI battery
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0
~
1
N/A
1
Effective Immediate
0: invalid 1:valid
So-39
Overtravel limit function
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0
~
2
N/A
1
Effective Immediate
0: invalid 1:valid
So-40
Delay time of lock-rotor protection
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
10
~
1000
10ms
100
Effective Immediate
So-41
Setting mechanical origin
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0
~
1
N/A
0
Effective Immediate
0: invalid 1:valid
So-42
Alarm output duty ratio
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
1
~
100
%
100
Effective Immediate
So-43
Encoder reset
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
0
~
1
N/A
0
Effective Immediate
0: invalid 1:valid
So-43 is used to reset motor encoder when encoder alarm occurs. User must hold down SET key to reset
keypad panel.
So-44
Paramter copy
Speed Position Torque
Setting range
Setting unit
Mfr’s value
Effect
Four- parameter
N/A
0000
Effective Immediate
Summary of Contents for FL20-S Series
Page 1: ......
Page 33: ...FL20 S Series 33 M3 structure Fig 3 1 5 Servo drive structure 3 ...
Page 35: ...FL20 S Series 35 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5 ...
Page 36: ...FL20 S Series 36 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6 ...
Page 37: ...FL20 S Series 37 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7 ...
Page 169: ...FL20 S Series 169 Fig 6 4 44FL20E Cam internal frameworkdiagram ...
Page 347: ...FL20 S Series 347 ...