FL20 Series
65
24 VDC
3.3 K
Servo drive
3.3 K
GP
DI1
DI8
24 VDC
3.3 K
Servo Drive
3.3 K
GP
DI1
DI8
Fig 4-3-13 passive-contact interface circuit
(2) Active contactor
Active contactors include photoelectrical sensor, Hall sensor, transistor type PLC.
24VDC
3.3 K
Servo Drive
Controller
GP
DI1
3.3K
GP
24VDC
DI1
Controller
Servo Drive
NPN type PNP type
Fig 4-3-14 active contactor interface circuit
2)
Digital output circuit
The output signal ALM and DO1~DO4 adopts photocoupler of Darlinton output which has strong ability for
drive and can drive small relay directly. It can drive heavier load by driving photocoupler. The max current
should not be higher than 50mA.
(1) Relay output
DC24V
Servo drive
Command controller
Fig 4-3-15 Relay output interface circuit