background image

How to Use This Manual

This manual provides detailed instructions on installation and
maintenance of Falk parallel shaft Type DH and right angle
Type DB gear drives. Use the table of contents below to locate
required information.

CAREFULLY FOLLOW THE INSTRUCTIONS IN THIS
MANUAL FOR OPTIMUM PERFORMANCE AND TROUBLE
FREE SERVICE OF YOUR FALK GEAR DRIVE.

Table of Contents

Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Shaft Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Tightening Torques. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Lubrication Recommendations. . . . . . . . . . . . . . . . . . . . . 4-6
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Stored and Inactive Gear Drives . . . . . . . . . . . . . . . . . . . . . 7
Changing Hand of Drive . . . . . . . . . . . . . . . . . . . . . . . . . . 8

APPENDIX

Appendix A: Fixed Torque Arm Installation . . . . . . . . . . . . . 9
Appendix B: Swing Base Installation . . . . . . . . . . . . . . . . . 10

Appendix C: Alignment Free Assembly & Installation –
Welded Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Appendix D: Alignment Free Assembly & Installation –
Cast Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14

Appendix E: Electric Fan Installation & Maintenance . . 15-16

Introduction

Credit for long service and dependable operation of a gear
drive is often given to the engineers who designed it, or the
craftsmen who constructed it, or the sales engineer who
recommended the type and size. Ultimate credit belongs to the
mechanic on the job who worked to make the foundation rigid
and level, who accurately aligned the shafts and carefully
installed the accessories, and who made sure that the drive
received regular lubrication. The details of this important job
are the subject of this manual.

NAMEPLATE —

Operate Falk gear drives only at power, speed and

ratio shown on the nameplate. Before changing any one of these,
submit complete nameplate data and new application conditions to
the Factory for correct oil level, parts, and application approval.

DISASSEMBLY AND ASSEMBLY —

Disassembly & assembly

instructions and parts guides are available from the Factory or
Sale Representatives. When requesting information, please give
complete data from the nameplate on the gear drive; Model,
M.O. Number, Date, RPM, and Ratio.

WARNING

:

Consult applicable local and national safety codes

for proper guarding of rotating members. Lock out power
source and remove all external loads from drive before
servicing drive or accessories

.

Warranty

Rexnord Industries, LLC (the “Company”) warrants that Drive
One gear drives (I) conform to Company’s published
specifications, and (II) are free from defects of material for three
years from the date of shipment.
Company does not warrant any non-Company branded
products or components (manufacturer’s warranty applies) or
any defects in, damage to, or failure of products caused by: (I)
dynamic vibrations imposed by the drive system in which such
products are installed unless the nature of such vibrations has
been defined and accepted in writing by Company as a

condition of operation; (II) failure to provide suitable
installation environment; (III) use for purposes other than those
for which designed, or other abuse or misuse; (IV) unauthorized
attachments, modifications or disassembly, or (V) mishandling
during shipping.

Installation Instructions

The following instructions apply to standard Falk Type DH & DB
drives. If a drive is furnished with special features, refer to the
supplementary instructions shipped with the drive.

WELDING —

Do not weld on the gear drive or accessories

without prior approval from the Factory. Welding on the drive
may cause distortion of the housing or damage to the bearings
and gear teeth. Welding without prior approval could void the
warranty.

NOTE:

Drives equipped with cooling fans may require removal

of shroud when installing foundation fasteners.

EFFECTS OF SOLAR ENERGY —

If the gear drive operates in

the sun at ambient temperatures over 38°C (100°F), then special
measures should be taken to protect the drive from solar energy.
This protection can consist of a canopy over the drive or reflective
paint on the drive. If neither is possible, a heat exchanger or other
cooling device may be required to prevent the sump temperature
from exceeding the allowable maximum.

MOUNTING POSITION —

Standard mounting positions for

types DH & DB are with the input and output shafts horizontal.
Allowable mounting angles for standard oil levels are;

Bridge

Slope

DH & DB

0° Up & 4° Down

± 1.5°

Consult the Factory for other angles.
If a gear drive is ordered for non-standard mounting positions,
refer to the instructions provided with the drive for oil levels and
bearing lubrication. If it is necessary to mount the gear drive in
a different position from which it was ordered, refer to the
Factory for required changes to provide proper lubrication.

FOUNDATION, GENERAL —

To facilitate oil drainage,

elevate the gear drive
foundation above the
surrounding floor level. If
desired, replace the drive oil
drain plug with a valve, but
provide a guard to protect the
valve from accidental opening
or breakage.
When an outboard bearing is used, mount drive and outboard
bearing on a continuous foundation or bedplate, and dowel
both in place.

Rexnord Industries, LLC, Geared Products, P.O. Box 492, Zip 53201-0492

168-056

3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone : 414-342-3131

(PN 2128959) February 2009

Fax: 414-937-4359 e-mail: [email protected] web: www.rexnord.com

NEW

Falk™ Drive One™ Model C Conveyor Drives

Owners Manual

Type D Series

Sizes M1220 thru M1250

(Page 1 of 16)

Type DH

Type DB

Summary of Contents for Falk Drive One D Series

Page 1: ...imposed by the drive system in which such products are installed unless the nature of such vibrations has been defined and accepted in writing by Company as a condition of operation II failure to provide suitable installation environment III use for purposes other than those for which designed or other abuse or misuse IV unauthorized attachments modifications or disassembly or V mishandling during...

Page 2: ...astener size Tighten fasteners to the torque specified in Table 1 Page 4 If the required torque is not attainable the fasteners may be tightened with a pre torque of 270 N m 200 lb ft then tightened an additional 60 of rotation with a slugging wrench to achieve proper torque After drive is aligned with driven equipment and bolted down align prime mover to drive input shaft Refer to Page 3 for coup...

Page 3: ...eflection Align the output shaft of the gear drive square and parallel with the driven shaft by placing a straightedge across the face of the sprockets or sheaves as illustrated Check horizontal shaft alignment by placing one leg of a square against the face of the sheave or sprocket with the spirit level on the horizontal leg of the square DO NOT over tighten belts or chains Adjust chains to manu...

Page 4: ... used only after approval from Factory Failure to use an approved lubricant voids warranty For drives operating outside the above temperature range refer to the Synthetic EP Lubricants section Synthetic lubricants can also be used in normal climates WARNING EP LUBRICANTS IN FOOD PROCESSING INDUSTRY EP lubricants may contain toxic substances and should not be used in the food processing industry wi...

Page 5: ...DA or NSF H 1 classification Consult the Factory Rexnord Industries LLC Geared Products P O Box 492 Zip 53201 0492 168 056 3001 W Canal St Zip 53208 4200 Milwaukee WI USA Telephone 414 342 3131 PN 2128959 February 2009 Fax 414 937 4359 e mail info rexnord com web www rexnord com NEW Falk Drive One Model C Conveyor Drives Owners Manual Type D Series Sizes M1220 thru M1250 Page 5 of 16 TABLE 3 Visco...

Page 6: ... level with new oil of the correct type and viscosity PERIODICALLY 1 Check the oil level of the drive when it is stopped and at ambient temperature Add oil if needed If the oil level is ABOVE the high oil level mark on the dipstick have the oil analyzed for water content Moisture in the oil may indicate that a seal or the heat exchanger is leaking If so replace the defective part immediately and c...

Page 7: ...using seal leaks GREASE LUBRICATED BEARINGS Torque Arm Most shaft mounted drives have a grease lubricated bearings in the torque arm Grease bearings during oil changes or at intervals of every 6 months or 2500 hours of operation whichever is less Stored Inactive Gear Drives Each gear drive is protected with a rust preventative that will protect parts against rust for a period of 4 months in an out...

Page 8: ...e 515 Gasket Eliminator or equivalent to the housing mating surface to the inside of the bolt pattern Assemble bottom plate to housing and tighten fasteners to 85 N m 62 lb ft Install previously remove pipe plugs into old dipstick and breather location Coat pipe threads with Loctite Pipe Joint Compound or equivalent prior to installation Position drive top side up Install dipstick fitting in housi...

Page 9: ... structure at this time 2 Secure the drive to the driven equipment via the rigid coupling connection 3 Mount the clevis to the drive or drive system Locate the position of the clevis to be mounted to the support structure Match drill the mounting holes for M24 Cl 8 8 or 1 inch Grade 5 fasteners or better 4 IF REQUIRED Mount plain spherical bearings into link Secure bearings with retainer plate and...

Page 10: ... gauge to ensure that all motor pads are firmly seated Motor mounting needs to be done in conjunction with coupling alignment to control angular and offset misalignment Refer to the coupling manufacturer s manual for specific instructions Bolt down the motor to the torque specified in Table 1 Page 4 Coupling Guard The coupling guard must be trimmed in order to fit the height and shaft extension re...

Page 11: ...luid Coupling Location of the fluid coupling on the high speed shaft of the drive is determined by the provided shaft spacer Install the fluid coupling on the high speed shaft of the gear drive per fluid coupling instructions Once the fluid coupling is installed the motor adapter plate can be mounted to the bell housing also being located by a register Measurements must be taken to accurately posi...

Page 12: ...e this is the amount each hub overhangs the shaft Once the overhang is determined install the hubs according to the instructions provided with the coupling Install the spacer sections and verify the gap is correct If not readjust the hub on the motor shaft If the coupling is furnished with an interference fit readjustment will not be possible take extra care in making measurements After the proper...

Page 13: ... installed removed without removing the motor see fluid coupling instructions for procedure Mount the coupling hubs to the drive high speed shaft and the motor shaft Hubs are to be mounted flush with the end of the shafts coupling hubs may be furnished with an interference fit Mount the motor to the bell housing apply Loctite 242 or equivalent fastener threads and tighten to proper torque Install ...

Page 14: ...the drive housing itself to maneuver the drive DO NOT lift by the motor lifting eye Mounting the Drive Mount the Alignment Free Drive to the driven equipment per Pages 1 and 2 of this manual With Alignment Free drive assembly supported rotate adjusting screw to move torque arm to desired position and to line up with foundation Torque Arm must be perpendicular in both directions 1 adjust screw if n...

Page 15: ...nd cooling use only DO NOT use if hazardous or explosive materials and vapors are present Guidelines For Installation Before connecting the electric fan check if the information on the fan motor name plate is in accordance with the actual main supply voltage phase and frequency Warning To reduce the risk of fire electric shock or personal injury observe the following 1 Switch off the main power su...

Page 16: ...hen cleaning fan both condensation holes Figure 3 Items 1 and 2 are to be temporarily plugged If this is not done guarantee is void When cleaning electrical equipment always use an approved cleaning agent Rexnord Industries LLC Geared Products P O Box 492 Zip 53201 0492 168 056 3001 W Canal St Zip 53208 4200 Milwaukee WI USA Telephone 414 342 3131 February 2009 PN 2128959 Fax 414 937 4359 e mail i...

Reviews: