Derating must be considered when the drive is installed at high altitude (greater than
1000m). This is because the cooling effect of drive is deteriorated due to the thin air, as
shown in Figure 3-2 that indicates the relationship between the elevation and rated
current of the drive.
Figure 3-2 Derating drive’s output current with altitude
Temperature derating
0.2 0.37 0.55 0.75 1.1 1.5 2.2 3.7
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
180
0.2
40 C 50 C 50 C 50 C 50 C 50 C 50 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
0.37
30 C 40 C 50 C 50 C 50 C 50 C 50 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
0.55
20 C 30 C 40 C 50 C 50 C 50 C 50 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
0.75
20 C 30 C 40 C 45 C 50 C 50 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
1.1
30 C 40 C 45 C 50 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
1.5
30 C 40 C 50 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
2.2
35 C 40 C 50 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
3.7
25 C 40 C 50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
4
30 C 40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
5.5
30 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
7.5
25 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
11
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
15
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
18.5
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
22
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
30
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
37
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
45
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
50 C
55
20 C
40 C
50 C
50 C
50 C
50 C
50 C
50 C
75
20 C
40 C
50 C
50 C
50 C
50 C
50 C
90
20 C
40 C
50 C
50 C
50 C
50 C
110
20 C
40 C
50 C
50 C
50 C
132
20 C
40 C
50 C
50 C
160
20 C
40 C
50 C
180
20 C
40 C
P
o
w
e
r o
f M
o
to
r (
kW
)
Power of drive (kW)
Iout
(
m
)
100%
90%
80%
1000
2000
3000
www.comoso.com
Summary of Contents for 10G-11-0015 Series
Page 2: ...www comoso com...