Parameter Reference
15-17
AC10 Inverter
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
FA63-
FA80
Reserved
15.10 Torque control parameters: FC00-FC40
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
FC00
Speed/torque control selection
0
:
Speed control
1
:
Torque control
2
:
Terminal switchover
0
√
FC01
Delay time of torque/speed control
switchover
(
S
)
0.0
~
1.0
0.1
╳
FC02
Torque accel/decel time (S)
0.1
~
100.0
1
√
FC03-
FC05
Reserved
FC06
Torque reference source
0: Digital given (FC09)
1: Analog input AI1
2: Analog input AI2
0
╳
FC07
Torque reference coefficient
0
~
3.000
3.000
╳
FC08
Reserved
FC09
Torque reference command value (%)
0
~
300.0
100.0
√
FC10-
FC13
Reserved
FC14
Offset torque reference source
0: Digital given (FC17)
1: Analog input AI1
2: Analog input AI2
0
╳
FC15
Offset torque coefficient
0~0.500
0.500
╳
FC16
Offset torque cut-off frequency (%)
0~100.0
10.00
╳
FC17
Offset torque command value (%)
0~50.0
10.00
√
FC18-
FC21
Reserved
FC22
Forward speed limit source
0: Digital given (FC23)
1: Analog input AI1
2: Analog input AI
0
╳
FC23
Forward speed limit (%)
0
~
100.0
10.00
√
FC24
Reverse speed limit source
0: Digital given (FC25)
1: Analog input AI1
2: Analog input AI
0
╳
FC25
Reverse speed limit (%)
0
~
100.0
10.00
√
FC26-
FC27
Reserved
FC28
Driving torque limit source
0: Digital given (FC30)
1: Analog input AI1
0
╳
www.comoso.com