![Parker 10G-11-0015 Series Product Manual Download Page 130](http://html1.mh-extra.com/html/parker/10g-11-0015-series/10g-11-0015-series_product-manual_3825607130.webp)
15-2
Parameter Reference
AC10 Inverter
Function
Code
Function
Definition
Setting Range
Mfr’s Value Change
F127
Skip Frequency A
0.00
~
590.0Hz
0.00
√
F128
Skip Width A
±2.50Hz
0.00
√
F129
Skip Frequency B
0.00
~
590.0Hz
0.00
√
F130
Skip Width B
±2.50Hz
0.00
√
F131
Running Display Items
0
-
Output frequency /
function code
1
-
Output rotary speed
2
-
Output current
4
-
Output voltage
8
-
PN voltage
16
-
PID feedback value
32
-
Temperature
64
-
Reserved
128
-
Linear speed
256
-
PID given value
512
-
Reserved
1024
-
Reserved
2048
-
Output power
4096
-
Output torque
0+1
+
2
+
4
+
8
=
15
√
F132
Display Items of Stop
0: frequency / function code
1: Keypad jogging
2: Target rotary speed
4: PN voltage
8: PID feedback value
16: Temperature
32: Reserved
64: PID given value
128: Reserved
256: Reserved
512: Setting torque
2
+
4
=
6
√
F133
Drive Ratio of Driven System
0.10
~
200.0
1.0
√
F134
Transmission-wheel Radius
0.001
~
1.000
0.001
√
F135
Reserved
F136
Slip Compensation
0
~
10
0
╳
F137
Modes of Torque Compensation
0: Linear compensation;
1: Square compensation;
2: User-defined multipoint
compensation
3: Auto torque compensation
3
╳
F138
Linear Compensation
1
~
20
subject to
inverter
model
╳
F139
Square Compensation
1
:
1.5
;
2
:
1.8
;
3
:
1.9
;
4
:
2.0
1
╳