15-12
Parameter Reference
AC10 Inverter
F615
Flycatching Rate
1
~
100
20
╳
F613-
F621
Reserved
F622
Dynamic Braking Mode
0: Fixed duty ratio
1: Auto duty ratio
0
√
F627
Current Limiting when Flycatching
50-200
100
╳
F631
VDC Adjustment Selection
0: invalid 1: valid
0
√
F632
Target voltage of VDC adjustor (V)
200-800
Subject to
inverter
model
√〇
F633-
F649
Reserved
F650
High-frequency performance
Setting range:
0: Invalid 1: Terminal enabled
2: Enabled mode 1
3: Enabled mode 2
2
×〇
F651
Switchover frequency 1
F652-150.00
100.00
√〇
F652
Switchover frequency 2
0-F651
95.00
√〇
F653-
F670
Reserved
15.7 Timing Control and Protection: F700-F770
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
F700
Selection of terminal free stop mode
0: free stop immediately;
1: delayed free stop
0
√
F701
Delay time for free stop and programmable
terminal action
0.0
~
60.0s
0.0
√
F702
Fan control mode
0:controlled by temperature
1: Running when inverter is powered
on
2: Controlled by running status
2
√
F703
Reserved
F704
Inverter Overloading pre-alarm Coefficient
(%)
50~100
80
╳
F705
Overloading adjusting gains
50~100
80
╳
F706
Inverter Overloading coefficient
%
120
~
190
150
╳
F707
Motor Overloading coefficient
%
20
~
100
100
╳
F708
Record of The Latest Malfunction Type
Setting range:
2: Over current (OC)
3: over voltage (OE)
4: input phase loss (PF1)
5: inverter overload (OL1)
6: under voltage (LU)
7: overheat (OH)
8: motor overload (OL2)
△
F709
Record of Malfunction Type for Last but One
△
F710
Record of Malfunction Type for Last but Two
△
www.comoso.com
Summary of Contents for 10G-11-0015 Series
Page 2: ...www comoso com...