74
74
75
Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the VMD
area settings, and the alarm occurrence notification can be configured on this page.
The "Alarm" page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
Configure the settings relating to the alarm action [Alarm]
Click the [Alarm] tab on the "Alarm" page. (
☞
Pages 26 and 27: How to display/operate the setup menu)
The settings relating to the alarm can be configured in this section. Refer to pages 77 and 79 for further information
about the settings relating to the alarm images and the alarm output terminal.
■
Alarm
[Terminal 1]
Determine how to use terminal 1.
Off:
Not used.
Alarm input:
Receives alarms.
Black & white input:
Receives the black & white swi-
tchover input. (When the input is set to On, the
black & white mode is activated.)
SW395
SC385
Default:
Off
[Terminal 2]
Determine how to use terminal 2.
Off:
Not used.
Alarm input:
Receives alarms.
Alarm output:
Alarm output will be carried out accord-
ing to the settings for "Alarm output terminal setup"
(
☞
page 79).
Default:
Off
[Terminal 3]
Determine how to use terminal 3.
Off:
Not used.
Alarm input:
Receives alarms.
AUX output:
AUX output will be supplied. The [AUX]
buttons will be displayed on the "Live" page.
Default:
Off
Note:
• AUX is a camera terminal that allows users to oper
-
ate (Open/Close) arbitrarily from the "Live" page.
For example, an operator can remotely control lights
in a place where the camera is installed by connect-
ing the terminal to the light controller.
• Refer to the installation guide for further information
about input/output rating of each terminal.
• While "Alarm input" is being selected, an alarm is
detected when the terminal status is changed to
"On". (Default)
It is possible to configure the setting so that an
alarm is detected when the terminal status is
changed to "Off". Refer to the "Readme" file on the
provided CD-ROM for further information about the
setting. Or refer to our website (http://panasonic.
net/pss/security/support/info.html) for further infor-
mation about the supported software.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the
"Alarm" page will be displayed.
[Command alarm]
Select "On" or "Off" to determine whether or not to
receive the command alarm.
The command alarm is the function that provides notifi-
cation of a Panasonic protocol alarm from the other
cameras. When "On" is selected, alarm actions will be
performed between multiple cameras.
Default:
Off
[Originating port number]
Select a port number to be used to receive the com-
mand alarm.
Available range:
1-65535
Unavailable port number:
Refer to the help window.
Default:
8181