76
Edit information of the registered administrator [Administrator Edit]
It is possible to edit the registered administrator information such as the password, operational level, etc.
Screenshot 1
Click the [User Mng.] button in the setup menu
(Advanced) and then click "Administrator Edit". The
"Administrator Edit" window will be displayed.
Step 1
Perform the settings for each item.
Refer to the following for further information about the
settings for each item.
Step 2
Click the [SET] button after completing the settings.
Important:
• The administrator information can be edited only
when logging in as the administrator.
• When the unit is being operated without changing
the default administrator name and password, the
pop-up window saying that it is recommended to
change the password will be displayed.
Setup items
■
Administrator Name
It is possible to edit the name of the administrator. Enter
4 to 14 alphanumeric characters for administrator name.
■
Password
Enter a password. Enter 4 to 8 alphanumeric characters
for a password.
Note:
To enhance the security, change the password for
an administrator periodically.
■
Level
Displays the operational level of the user. The user level
of the administrators is "LV1" and it is impossible to
change it.
Operable functions for LV1 can be set in the "User
Level" menu (page 80).
■
Priority
Display the settings to assign priorities to operate this
unit in case two or more users access this unit simulta-
neously.
The priority of the administrators is "0" and it is impossi-
ble to change it.
■
Default Screen
Select a startup display to be displayed after login from
the following.
CAM1 - 32:
Displays live images from the selected cam-
era channel on a single screen.
4A - 4H:
Images of the camera group (A-H) consisted
from 4 camera channels in advance will be switched
and displayed sequentially on a 4-Screen.
The camera group settings can be performed on the
"Monitor Display" settings of the setup menu
(Advanced) ("System" - "Basic Setup" - "Monitor
Display"). Refer to page 42 for further information.
SEQ:
Images will be displayed in the sequential display.
The operational settings of the sequential display
can be performed on the "Sequence Setup" setting
of the setup menu ("Camera" - "Sequence Setup").
■
Camera Partitioning
Display a controllable range for each camera channel.
The camera partitioning setting of the administrators is
"View/Operate" and it is impossible to change it.
View/Operate:
Both displaying live images and control-