49
Functions for Events [Event]
Perform the settings for event actions of each event type (site alarm, terminal alarm and command alarm). Refer to
the provided operating instructions for further information about each event type.
Basic settings for event actions [Basic Setup]
Perform the settings relating to event actions such as the alarm output duration and the buzzer sound duration of
each camera channel at an event occurrence (site alarm, terminal alarm, command alarm).
Screenshot 1
Click the [Event] button in the setup menu (Advanced)
and then click "Basic Setup". The "Basic Setup" window
will be displayed.
Step 1
Perform the settings for each item.
■
Alarm Output
Select the alarm output duration.
The following are available for alarm output duration.
OFF:
No alarm output is supplied.
1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min/2 min/
3 min/4 min/5 min
EXT:
The alarm output will continue until the [ALARM
RESET] button is clicked.
REC:
The alarm output will be supplied during recording
is being performed.
■
Buzzer
Select ON or OFF to set whether or not to sound the
buzzer at an event occurrence. The following are avail-
able for buzzer sound duration.
OFF:
The buzzer will not sound.
1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min/2 min/
3 min/4 min/5 min
EXT:
The buzzer will continue until the [ALARM
RESET] button is clicked.
REC:
The buzzer will sound only during the event
recording is being performed.
Step 2
Click the [SET] button after completing the settings.