Available commands are listed below.
C Set a classifier index.
Press "C" to change the command prompt to "Enter Classifier Index>." Enter a
classifier index from 1 to 65535.
S Set a source MAC address to be filtered.
Press "S" to change the command prompt to "Enter source MAC address>." Enter
the sender MAC address, such as xx:xx:xx:xx:xx:xx. Then, "Enter source MAC
address mask length>" is displayed. Enter a bit mask length of source MAC
address.
D Set a destination MAC address to be filtered.
Press "D" to change the command prompt to "Enter designation MAC address>."
Enter the destination MAC address, such as xx:xx:xx:xx:xx:xx. Then, "Enter
destination MAC address mask length>" is displayed. Enter a bit mask length of
destination MAC address.
V Set VLAN ID to be filtered.
Press "V" to change the command prompt to "Enter VLAN ID>." Enter from 1 to
4094 for VLAN ID.
P Set DSCP value to be filtered.
Press "P" to change the command prompt to "Enter DSCP value (0-63)>." Enter
from 0 to 63 for DSCP value.
R Set a protocol to be filtered.
Press "R" to change the command prompt to "Select protocol>." For TCP, enter
"1." For UDP, "2." For ICMP, "3." For IGMP, "4." For RSVP, "5." For other protocols,
"6."
O Set a source IP address to be filtered.
Press "O" to change the command prompt to "Enter source IP address>." Enter a
source IP address. Then, "Enter source IP address mask length>" is displayed.
Enter a bit mask length of source IP address.
E Set a destination IP address to be filtered.
Press "E" to change the command prompt to "Enter destination IP address>."
Enter a destination IP address. Then, "Enter destination IP address mask length>"
is displayed. Enter a bit mask length of destination IP address.
U Set a TCP/UDP source port number to be filtered.
Press "U" to change the command prompt to "Choose single port or defined port
range (S/D)>." To designate one, press "S." Then, the command prompt changes
to "Enter source layer 4 port." Enter the source port number. To designate by a
range, enter "D." Then, the command prompt changes to "Enter starting source
port>" and "Enter final source port>." Enter the starting and final source port
numbers.
T Set a TCP/UDP destination port number to be filtered.
Press "T" to change the command prompt to "Choose single port or defined port
range (S/D)>." To designate one, press "S." Then, the command prompt changes
to "Enter destination layer 4 port>." Enter the destination port number. To
designate by a range, enter "D." Then, the command prompt changes to "Enter
starting destination port>" and "Enter final destination port>." Enter the starting
and final destination port numbers.
I Set IEEE802.1p priority to be filtered.
Press "I" to change the command prompt to "Enter 802.1p priority>." Enter
802.1p priority in a range from 0 to 7.
Summary of Contents for Switch-M12PWR
Page 17: ...17 Fig 2 2 Mounting to Wall ...
Page 20: ...20 function does not work Therefore use a cross cable to connect them ...
Page 30: ...30 ...
Page 36: ...36 ...
Page 49: ...49 ...
Page 69: ...69 ...
Page 81: ...81 setting and the management VLAN status of VLAN ID 1 is UP ...
Page 96: ...96 Press S Q Return to the previous menu ...
Page 98: ...98 ...
Page 122: ...122 Q Return to the previous menu ...
Page 125: ...125 ...
Page 130: ...130 ICMP Type Displays the ICMP type ...
Page 156: ...156 Threshold Displays the threshold of the number of packets per second ...
Page 173: ...173 Fig 4 7 49 Display of values accumulated after resetting the counters ...
Page 185: ...185 Q Return to the previous menu ...
Page 211: ...211 Q Return to the previous menu ...
Page 232: ...232 IEEE8021 PAE MIB IEEE802 1X IEEE8023 LAG MIB IEEE 802 3ad ...
Page 237: ...237 IEEE 802 3af standard ...
Page 240: ...240 P0813 1084 ...