Chapter 4
Settings — [PROJECTOR SETUP] menu
ENGLISH - 127
10) After the name is input, press
asqw
to select [OK], and press the <ENTER> button.
f
Saving of the lens memory is completed, and returns to the
[LENS MEMORY SAVE]
screen.
f
If you press
asqw
to select [CANCEL] and then press the <ENTER> button, the lens memory will not be
saved.
f
If you press
asqw
to select [DEFAULT] and press the <ENTER> button, the entered name will not be
registered and the default name will be used.
f
If you select [OK] without entering any characters and press the <ENTER> button, the default name will be
used.
Note
f
The numeric value information of the periphery focus position is displayed only when one of the following lenses is attached.
g
ET-EMW200, ET-EMW300, ET-EMW400, ET-EMW500, ET-EMU100
Loading the lens position
1) Press
as
to select [LENS].
2) Press the <ENTER> button.
f
The
[LENS]
screen is displayed.
3) Press
as
to select [LENS MEMORY].
4) Press the <ENTER> button.
f
The
[LENS MEMORY]
screen is displayed.
5) Press
as
to select [LENS MEMORY LOAD].
6) Press the <ENTER> button.
f
The
[LENS MEMORY LOAD]
screen is displayed.
f
The name of the saved lens memory and its lens position information ([VERTICAL POSITION]/
[HORIZONTAL POSITION]/[FOCUS POSITION]/[ZOOM POSITION]/[PERIPHERY FOCUS POSITION])
are displayed in the
[LENS MEMORY LOAD]
screen.
7) Press
as
to select the item to load, and press the <ENTER> button.
f
The confirmation screen is displayed.
8) Press
qw
to select [OK], and press the <ENTER> button.
f
The lens will automatically move to the lens position (vertical position, horizontal position, focus position,
zoom position, and periphery focus position) of the loaded lens memory.
Note
f
Lens memory is not guaranteed to be 100 % reproduced. Readjust the focus, periphery focus, zoom, and lens shift after loading the lens
memory if required.
f
If the projection lens is replaced, execute the [PROJECTOR SETUP] menu
→
[LENS]
→
[LENS CALIBRATION], readjust the focus,
periphery focus, zoom, and lens shift, and save the lens memory again.
f
Lens memory with numeric value information of the periphery focus position displayed is the lens memory saved when one of the following
lenses is attached.
g
ET-EMW200, ET-EMW300, ET-EMW400, ET-EMW500, ET-EMU100
f
The saved lens memory is loaded in order every time the <FUNCTION> button is pressed when [LENS MEMORY LOAD] is assigned to the
<FUNCTION> button.
Deleting a lens memory
1) Press
as
to select [LENS].
2) Press the <ENTER> button.
f
The
[LENS]
screen is displayed.
3) Press
as
to select [LENS MEMORY].
4) Press the <ENTER> button.
f
The
[LENS MEMORY]
screen is displayed.
5) Press
as
to select [LENS MEMORY EDIT].