№
SR-ZSV00039
-
5
-
Motor Business Unit, Appliances Company, Panasonic Corporation
2
-
3
Input/Output Signal Allocation
The assignment of the input/output signals can be changed from the default setting.
2
-
3
-
1
Allocation of Input Signal
An input signal that you wish can be assigned to an input pin of the I/F connectors. It is also possible to change the
logic.
Note that for some signals, assignment is limited. For details, see (2) "Change the default assignment for input
signals."
(
1) Use the default signal assignment
The following table shows the default setting for the signal assignment.
Default status
Input signals*2
Corresponding
parameter
Default value
(): Decimal
number
Signal
Logic *1
SI1 input
Pr4.00
00000003h
(3)
SRV-ON
a connect
SI2 input
Pr4.01
00000004h
(4)
A-CLR
a connect
SI3 input
Pr4.02
00000007h
(7)
CL
a connect
SI4 input
Pr4.03
00000088h
(136)
INH
b connect
SI5 input
Pr4.04
00000082h
(130)
NOT
b connect
SI6 input
Pr4.05
00000081h
(129)
POT
b connect
*1 "a connect" and "b connect" represent the following respectively:
a connect : A signal input is open with COM-, and thus the function is invalid (OFF state).
A signal input is connected with COM-, and thus the function is valid (ON state).
b connect : A signal input is open with COM-, and thus the function is valid (ON state).
A signal input is connected with COM-, and thus the function is invalid (OFF state).
In this specification, a signal input is defined ON when its function is valid; OFF when the function is invalid.
*2 For pin numbers assigned as input signals SI1 – SI10, see Specifications.
*3 The mark "-" displays that there is no function assigned.