SR-ZSV00039
-
64
-
Motor Business Unit, Appliances Company, Panasonic Corporation
7
-
3
Warning Functions
A warning is generated before the protective function is activated. This allows you to check the status such as an
overload in advance.
In principle, a warning will automatically return to the state where it is not issued if the faulty state is
corrected. However, the warning state will be kept during latch duration as shown in the following figure.
To clear a latched warning before the latch time expires, perform the procedure taken to execute an alarm
clear.
(1)Related parameters
Category
No.
Parameter
Setup range
Unit
Function
4
40
Selection of alarm
output 1
0
11
Selects the warning output by the Warning output 1(WARN1).
Set value 0: OR output of all warnings
1 and after: See the following table.
4
41
Selection of alarm
output 2
0
~
11
-
Select the warning output by the Warning output 2(WARN2).
Set value 0: OR output of all warnings
1 and after: See the following table.
6
27
Alarm latch time selection
0
~
10
-
Sets the warning latch time.
0: Infinite latch time
1 to 10: Latch time 1 to 10[s]
6
38
Alarm mask setup
-32768
~
32767
-
Performs the mask setting for warning detection. If the corresponding bit is
set to 1, the corresponding warning detection is disabled.
(2)
Warning type
Warning
number
Warning
Item
Pr6.27 *1
Pr4.40/Pr4.41
*2
Pr6.38-compatible
bit *3
A0
Overload
The load factor has exceeded 85%
of the protection level.
○
1
bit7
A1
Regeneration over
The regeneration load factor has
exceeded 85% of the protection
level.
○
2
bit5
A4
Encoder
communication
The count of consecutive encoder
communication errors has
exceeded the protection level.
○
5
bit4
A6
Oscillation
detection warning
Oscillation state was detected.
○
7
bit9
AA
Over heat warning
When the temperature of Amp
over the over heat label
○
11
bit11
*1 For “
”, you can set a value between 1 and 10s in Pr6.27 “Alarm latch time selection”, or set no ti
me limit. Battery warnings and life warnings are set with “no time limit.”
*2 Select the warning output by the Warning output signal 1 (WARN1) and Warning output signal 2 (W
ARN2) using Pr4.40 “Selection of alarm output 1” and Pr4.41 “Selection of alarm output 2”. If set to
0, OR output of all warnings will be output. Also, do not set a value other than the set values liste
d in the above table.
*3 Each warning detection can be masked using Pr6.38 “Alarm mask setup”. The supported bits are listed in the
table. Bit=1 masks the warning detection.
*4 The encoder overheat is effective only during using the 20 bit incremental serial encoder . It becomes invalid for other
encoders.