Category 3:
(
none
)
Category 4: I/O & Monitor
Category
No.
Parameter
Unit
Setup range
Function/description
Attribute
4
00
SI1 input selection
-
0
00FFFFFFh
To set the function and logic of SI1.
Power reset
01
SI2 input selection
-
0
00FFFFFFh
To set the function and logic of SI2.
Power reset
02
SI3 input selection
-
0
00FFFFFFh
To set the function and logic of SI3.
Power reset
03
SI4 input selection
-
0
00FFFFFFh
To set the function and logic of SI4.
Power reset
04
SI5 input selection
-
0
00FFFFFFh
To set the function and logic of SI5.
Power reset
05
SI6 input selection
-
0
00FFFFFFh
To set the function and logic of SI6.
Power reset
10
SO1 output selection
-
0
00FFFFF
Fh
To assign a function to the SO1.
Power reset
11
SO2 output selection
-
0
00FFFFF
Fh
To assign a function to the SO2.
Power reset
12
SO3 output selection
-
0
00FFFFF
Fh
To assign a function to the SO3.
Power reset
31
Positioning complete
(In-position) range
Comman
d unit
0
262144
To set the allowable number of pulses in the positioning
complete signal (INP).
The unit is as per Pr5.20 “Position setup unit select “.
Always valid
32
Positioning complete
(In-position) output
setup
-
0
3
To select the criteria for the in-position output.
Always valid
33
INP hold time
ms
0
30000
To set the INP hold time.
Always valid
34
Zero-speed
R/min
10
20000
To set the threshold to detect the zero speed (ZSP).
Always valid
36
At-speed (Speed
arrival)
r/min
10
20000
To set the threshold to detect the at-speed
(AT-SPEED).
Always valid
37
Mechanical brake
action at stalling
setup
ms
0
10000
To set the stop time mechanical brake operation setting.
The established resolution is 2ms. For example, if the
setting value = 11, it will be 12ms.
Always valid
38
Mechanical brake
action at running
setup
ms
0
10000
To set the run time mechanical brake operation setting.
The established resolution is 2ms. For example, if the
setting value = 11, it will be 12ms.
Always valid
39
Brake release speed
setup
r/min
30
3000
To set the speed threshold for run time mechanical
brake output determination.
Always valid
40
Selection of alarm
output 1
-
0
10
To select the warning type for the warning 2 to output.
Always valid
41
Selection of alarm
output 2
-
0
10
To select the warning type for the warning 2 to output.
Always valid
42
2
nd
Positioning com-
plete (In-position)
range
Comman
d unit
0
262144
Sets the allowable number of pulses in the positioning
complete signal 2(INP2).
The unit is as per Pr5.20 “Position setup unit select “.
Always valid