SR-ZSV00039
-
6
-
Motor Business Unit, Appliances Company, Panasonic Corporation
(2) Change the default assignment for input signals
To reassign an input signal, change the following parameter.
Category
No.
Parameter
Setup range
Unit
Function
4
00
SI1 input selection
0~
00FFFFFFh
-
To assign a function to the input SI1.
Set this parameter with the hexadecimal system. *1
Following the hexadecimal form, set each control mode as follows:
000000**h
Enter a function number in the place marked with "**."
Please refer to the function number table shown later in this section.
The setting of logics is also included in the function numbers.
If you wish to assign to a pin DIV1_a connect,
the setting will be
0000000Ch.
4
01
SI2 input selection
0~
00FFFFFFh
-
To assign a function to the input SI2.
Set this parameter with the hexadecimal system.
Settings can be made in the same way for Pr4.00.
4
02
SI3 input selection
0~
00FFFFFFh
-
To assign a function to the input SI3.
Set this parameter with the hexadecimal system.
Settings can be made in the same way for Pr4.00.
4
03
SI4 input selection
0~
00FFFFFFh
-
To assign a function to the input SI4.
Set this parameter with the hexadecimal system.
Settings can be made in the same way for Pr4.00.
4
04
SI5 input selection
0~
00FFFFFFh
-
To assign a function to the input SI5.
Set this parameter with the hexadecimal system.
Settings can be made in the same way for Pr4.00.
4
05
SI6 input selection
0~
00FFFFFFh
-
To assign a function to the input SI6.
Set this parameter with the hexadecimal system.