1-9
1.3 Unit Types
1.3.1 Remote I/O System "MEWNET-F" Components
Name
Specifications
I/O
allocation
Model
No.
FP2 Multi-wire
Link Unit
A master station is configured with the CPU unit of FP2,
FP2SH, and controlsslave stations.
16SE
Note4)
AFP2720
Master
station FP3 Remote I/O
Master Unit
A master station is configured with the CPU unit of FP3
FP10, and controlsslave stations.
16SE
Note4)
AFP3742
FP2 Remote I/O
Slave Unit
This unit is used for decentralized allocation of I/O using
the FP2 system as a slave station. It is controlled by the
master unit.
―――
AFP2745
FP3 Remote I/O
Slave Unit
This unit is used for decentralized allocation of I/O using
the FP3 system as a slave station. It is controlled by the
master unit.
―――
AFP3745
12 V DC input/
0.2 A Tr output
16-point input, 16-point
output
16X16Y AFP87445
FP I/O terminal
baord
[MIL connector
type]
Note1)
24 V DC input/
0.2 A Tr output
16-point input, 16-point
output
16X16Y AFP87446
24 V DC input/
0.2 A Tr output
16-point input, 16-point
output
16X16Y AFP87444
FP I/O terminal
board [Terminal
block type]
24 V DC input/
2 A Ry. output
16-point input, 8-point
output
16X16Y AFP87432
8-point
input
16X AFP87421
Input unit
24 V DC input
16-point
input
16X AFP87422
8-point
output
16Y AFP87423
FP I/O
Terminal
Unit
(Basic)
Output unit
0.5 A Tr. output
16-point
output
16Y AFP87424
8-point
input
16X AFP87425
Input unit
24 V DC input
16-point
input
16X AFP87426
8-point
output
16Y AFP87427
FP I/O Terminal
Unit
Controlled as
a slave
station. Up to
32 points can
be added.
(Operating
voltage: 24 V
DC)
FP I/O
Terminal
Expansion
Unit
Note2)
Output unit
0.5 A Tr. output
16-point
output
16Y AFP87428
Power supply voltage: 24 V
DC
32X32Y AFP1732
FP1 I/O Link Unit
Combined with FP1, and
exchanges contact
information with the master
station (FP2, FP2SH, FP3,
FP10SH).
Note3)
Power supply voltage: 100 V
AC to 240 V AC
32X32Y AFP1736
Slave station
FP0 I/O Link Unit
Combined with FP0 and
exchanges contact
information with the master
station (FP2, FP2SH, FP3,
FP10SH).
Power supply voltage: 24 V
DC
32X32Y AFP0732
Power supply voltage: 12 V
DC
32X32Y AFC1731
FP-M I/O link
board
Combined with FP-M, and
exchanges contact
information with the master
station (FP2, FP2SH, FP3,
FP10SH).
Power supply voltage: 24 V
DC
32X32Y AFC1732
Note1) Power supply cable (1 m in length) APL9511 x 1 pc is supplied.
Note2) PL Mark II expansion cable (8 cm in length) APL2510 x 1 pc is supplied.
Note3) FP1 expansion cable (7 cm in length) AFP1510 x 1 pc is supplied.
Note4) When using the editing software FPWIN GR, the number of occupied I/O points can be set to 0
(0SE).
Summary of Contents for MEWNET-F
Page 9: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 19: ...Chapter 2 Part Names and Functions ...
Page 40: ...2 22 ...
Page 41: ...Chapter 3 Unit Specifications ...
Page 52: ...3 12 ...
Page 53: ...Chapter 4 Installation and Wiring ...
Page 62: ...4 10 ...
Page 63: ...Chapter 5 Connection for the Remote I O System ...
Page 75: ...Chapter 6 Remote I O Map ...
Page 84: ...6 10 ...
Page 85: ...Chapter 7 Operation Modes for Controlling MEWNET F ...
Page 97: ...Chapter 8 Control by MEWNET F ...
Page 108: ...8 12 Flowchart ...
Page 110: ...8 14 ...
Page 111: ...Chapter 9 Troubleshooting ...
Page 120: ...9 10 ...
Page 121: ...9 11 9 5 2 When the ALARM LED is ON ...
Page 122: ...9 12 9 5 3 When the Communication LED on the Master Unit does Not Flash Normally ...
Page 123: ...9 13 When the COMM LED is OFF ...
Page 124: ...9 14 When the COMM LED is ON ...
Page 125: ...9 15 9 5 4 When the Communication LED on a Slave Station does Not Flash Normally ...
Page 126: ...9 16 When the COMM LED is OFF ...
Page 127: ...9 17 When the COMM LED is ON ...
Page 128: ...9 18 9 5 5 When the CPU does Not Operate ...
Page 129: ...9 19 9 5 6 When the Input Output Function of a Slave Station does Not Work ...
Page 130: ...9 20 9 5 7 When the Memory Access Function for the Advanced Unit s Memory does Not Work ...
Page 134: ...9 24 ...
Page 135: ...Chapter 10 Dimensions ...
Page 136: ...10 2 10 1 FP2 Multi wire Link Unit AFP2720 10 2 FP3 Remote I O Master Unit AFP3742 ...
Page 137: ...10 3 10 3 FP2 Remote I OSlave Unit AFP2745 10 4 FP3 Remote I OSlave Unit AFP3745 ...
Page 141: ...10 7 10 8 FP0 I O Link Unit AFP0732 ...
Page 142: ...10 8 ...
Page 143: ...Chapter 11 Appendix 1 I O Link With FP1 ...
Page 147: ...11 5 11 3 Part Names and Functions ...
Page 159: ...Chapter 12 Appendix 2 I O Link With FP0 ...
Page 164: ...12 6 ...
Page 166: ......
Page 167: ......
Page 168: ...FAF 35E 1 200803 http www mew co jp ac e fasys 2008 ...