11-7
11.4 Specifications
11.4.1 General Specifications
Type
Consumption current
Weight
Power supply
voltage
Product No.
FP1 I/O Link Unit
[DC Power Supply Type]
0.1 A or less
Note1)
Approx.
230g
20.4 V DC to
26.4 V DC
AFP1732
FP1 I/O Link Unit
[AC Power Supply Type]
0.08 A or less
(When using 100 V)
0.06 A or less
(When using 200 V)
Note2)
Approx.
380g
85 V AC to
264 V AC
AFP1736
Note1) When connecting an expansion unit that has no power supply after an I/O link unit, the
consumption current is 0.2 A or less.
Note2) When connecting an expansion unit that has no power supply after an I/O link unit, the
consumption current is 0.12 A or less (when using 100 V)/0.08 A or less (when using 200 V).
11.4.2 Performance Specifications
Item
Specifications
No. of slots used by I/O link unit
1 slot
No. of I/O points occupied by I/O link unit
64 points (Input: 32 Output: 32 point)
Note1)
Allocation using remote I/O map
32X32Y
Note1) On the FP1, the input X70 to X8F and the output Y70 to Y8F are used (fixed).
Reference:
<Chapter3 Unit Specifications>
Summary of Contents for MEWNET-F
Page 9: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 19: ...Chapter 2 Part Names and Functions ...
Page 40: ...2 22 ...
Page 41: ...Chapter 3 Unit Specifications ...
Page 52: ...3 12 ...
Page 53: ...Chapter 4 Installation and Wiring ...
Page 62: ...4 10 ...
Page 63: ...Chapter 5 Connection for the Remote I O System ...
Page 75: ...Chapter 6 Remote I O Map ...
Page 84: ...6 10 ...
Page 85: ...Chapter 7 Operation Modes for Controlling MEWNET F ...
Page 97: ...Chapter 8 Control by MEWNET F ...
Page 108: ...8 12 Flowchart ...
Page 110: ...8 14 ...
Page 111: ...Chapter 9 Troubleshooting ...
Page 120: ...9 10 ...
Page 121: ...9 11 9 5 2 When the ALARM LED is ON ...
Page 122: ...9 12 9 5 3 When the Communication LED on the Master Unit does Not Flash Normally ...
Page 123: ...9 13 When the COMM LED is OFF ...
Page 124: ...9 14 When the COMM LED is ON ...
Page 125: ...9 15 9 5 4 When the Communication LED on a Slave Station does Not Flash Normally ...
Page 126: ...9 16 When the COMM LED is OFF ...
Page 127: ...9 17 When the COMM LED is ON ...
Page 128: ...9 18 9 5 5 When the CPU does Not Operate ...
Page 129: ...9 19 9 5 6 When the Input Output Function of a Slave Station does Not Work ...
Page 130: ...9 20 9 5 7 When the Memory Access Function for the Advanced Unit s Memory does Not Work ...
Page 134: ...9 24 ...
Page 135: ...Chapter 10 Dimensions ...
Page 136: ...10 2 10 1 FP2 Multi wire Link Unit AFP2720 10 2 FP3 Remote I O Master Unit AFP3742 ...
Page 137: ...10 3 10 3 FP2 Remote I OSlave Unit AFP2745 10 4 FP3 Remote I OSlave Unit AFP3745 ...
Page 141: ...10 7 10 8 FP0 I O Link Unit AFP0732 ...
Page 142: ...10 8 ...
Page 143: ...Chapter 11 Appendix 1 I O Link With FP1 ...
Page 147: ...11 5 11 3 Part Names and Functions ...
Page 159: ...Chapter 12 Appendix 2 I O Link With FP0 ...
Page 164: ...12 6 ...
Page 166: ......
Page 167: ......
Page 168: ...FAF 35E 1 200803 http www mew co jp ac e fasys 2008 ...