- 30 -
Operation Function
< 16-speed mode >
Control terminal number
I
I
I
I3
I
I
I
I4
I
I
I
I5
I
I
I
I6
Frequency setting
OFF
OFF
OFF
OFF
0th speed frequency
ON
OFF
OFF
OFF
1st speed frequency
OFF
ON
OFF
OFF
2nd speed frequency
ON
ON
OFF
OFF
3rd speed frequency
OFF
OFF
ON
OFF
4th speed frequency
ON
OFF
ON
OFF
5th speed frequency
OFF
ON
ON
OFF
6th speed frequency
ON
ON
ON
OFF
7th speed frequency
OFF
OFF
OFF
ON
8th speed frequency
ON
OFF
OFF
ON
9th speed frequency
OFF
ON
OFF
ON
10th speed frequency
ON
ON
OFF
ON
11th speed frequency
OFF
OFF
ON
ON
12th speed frequency
ON
OFF
ON
ON
13th speed frequency
OFF
ON
ON
ON
14th speed frequency
ON
ON
ON
ON
15th speed frequency
•
“ON” and “OFF” indicate the connection between each frequency setting
selection terminal and the “G” terminal.