Detailed Parameter Description
No. Parameter
name
Description
Used to select the signal type when the relay output terminals (NC, COM2
and NO) are used.
Relay output
selection
■
●
●
●
●
●
●
●
(TRIP):
Trip output signal
(During trip: NC - COM2: Open, NO - COM2: Closed)
(STaBLe): Arrival signal
(At arrival: NC - COM2: Open, NO - COM2: Closed)
(RUN): Run/stop
signal
(During operation: NC - COM2: Open, NO - COM2: Closed)
(FREE): Free-run
signal
(During free-run: NC - COM2: Open, NO - COM2: Closed)
(Fwd):
CCW operation signal
(During CCW operation: NC - COM2: Open, NO - COM2: Closed)
(Rev):
CW operation signal
(During CW operation: NC - COM2: Open, NO - COM2: Closed)
(ChecK-F):Output frequency detection signal
→
See
[
Comparative frequency A] and
[
Comparative frequency B].
(ChecK
ー
C): Motor current detection signal
→
See
[
Motor current detection level].
Motor current
detection level
When [
Output signal
①
selection], [
Output signal
②
selection] and [
Relay output selection] are set to
, this
parameter is used to define the current level to be detected as a
percentage relative to the inverter’s rated current.
When the motor current exceeds the specified detection level, the output
terminal is activated. When the motor current falls below the detection
level, the output turns OFF.
Output signal
①
polarity selection
Reverses the polarity of output signal on output terminals [O1] and
[COM1].
■
(NORmal)
:
transistor: “ON” ... normal polarity
●
(REVerse)
:
transistor: “OFF” ... reversed polarity
Current limit
operating point
Limits the motor current at the specified operating point.
The set value is a percentage relative to the inverter’s rated current.
■
: Factory setting