44
Parameter Description
Parameter setting
No. Parameter
name
Adjustment range
Min. unit
Factory setting Check
∗
1
PID function selection
Disables PID control
-
Enables PID control (Reverse)
-
Enables PID control (Normal)
Proportional (P) gain setting
0.2 - 5
0.1
1.0
Integral ( I ) time constant setting
0.0 - 150.0 sec
0.1 sec
1.0 sec
Differential (D) time
constant setting
0.0 - 100.0 sec
0.1 sec
0.0 sec
PID scale ratio setting
0.01 - 99.99 0.01
1.0
Feedback input method
setting
0 – 5 V input to FIN1
0 – 10 V input to FIN1
4 – 20 mA input to FIN2
Equipment number
80 - 9F
1
81
Communication speed
2400, 4800, 9600, 19200bps
9600
Communication
standard
Bit length: 8, Parity: None, Stop bit: 1
Bit length: 8, Parity: None, Stop bit: 2
Bit length: 8, Parity: Odd, Stop bit: 1
Bit length: 8, Parity: Odd, Stop bit: 2
Bit length: 8, Parity: Even, Stop bit: 1
Bit length: 8, Parity: Even, Stop bit: 2
Bit length: 7, Parity: None, Stop bit: 1
Bit length: 7, Parity: None, Stop bit: 2
Bit length: 7, Parity: Odd, Stop bit: 1
Bit length: 7, Parity: Odd, Stop bit: 2
Bit length: 7, Parity: Even, Stop bit: 1
Bit length: 7, Parity: Even, Stop bit: 2
Communication response time
5 - 1000ms
1ms 10ms
Number of communication retries
0 - 8
1
Protocol timeout
1 - 255 sec
1 sec
2 sec
Parameter extraction
Parameter No.
∗
1 Parameters
marked
by
in the Check column are tripped for safety if modified or
memorized.
Cancel the trip before use.