65
Extracting and locking parameters
Register numbers of parameters that can be edited. After that, these parameters can be
edited by calling the number.
Example: Only [
Acceleration time] can be set with
.
Operation panel
Step
Switch
Display on LED
Remarks
①
Turn power
on
•
Default mode: Monitor
(reading output frequency)
②
Select
[
]
Press
DATA SET .
Using
△
, select
[99].
Parameter value
-
•
Parameter number mode
③
Select
[
]
Press
DATA SET .
Using
△
, select
[21].
-
-
•
Parameter value mode
④
Register
[
]
Press
DATA SET .
Press
△
.
Press
DATA SET .
-
-
-
•
Parameter
value
mode
•
Parameter is saved.