5
1
No. Parameter
name
Description
Output signal
①
selection
Output signal
②
selection
Output signal to terminals [O1], [O2]-[COM1] can be selected as shown below.
●
(TRIP)
:
trip output signal (trip: on)
●
(STaBLe)
:
arrival signal (arrive: on)
●
(RUN)
:
run/stop signal (run: on)
●
(FREE)
:
free-run signal (free-run: on)
●
(Fwd)
: running in CCW signal (CCW: on)
●
(Rev)
: running in CW signal (CW: on)
●
(ChecK-F)
:
Output frequency detection signal
→
See [
Comparative frequency A] and [
Comparative frequency B].
●
(ChecK-C)
:
Motor current detection signal
→
See [
Motor current detection level].
●
(DC-Brake)
:
DC braking signal (DC braking: ON)
●
(CAUS)
:
Trip cause output signal
At occurrence of trip, the following signal is output.
∗
The polarity for [
Output signal
①
selection] can be inverted by [
Output
signal
①
polarity selection].
Trip
ON duration
OFF duration
Constant overcurrent
Continual
Overcurrent detected by current sensor
1 sec
2 sec
Overcurrent during acceleration
3 sec
1 sec
Overcurrent during deceleration
1 sec
3 sec
Overvoltage
1 sec
1 sec
External forced trip
0.25 sec
0.25 sec
Electronic thermal
0.9 sec
0.1 sec
Radiator fin overheat protection
2 sec
2 sec
CPU error
0.1 sec
0.4 sec
Communication error
0.4 sec
0.4 sec
Self-diagnosis shut-off
0.5 sec
0.5 sec