49
No. Parameter
name
Description
[2nd V/F selection] is used to specify a particular V/F pattern.
The upper pattern
and the lower pattern
specified by [2nd V/F base frequency] and [2nd V/F boost], as well as the
ordinary V/F pattern can be selected.
■
Ordinary pattern
●
Upper pattern
2nd V/F selection
2nd V/F base
frequency
2nd V/F boost
●
Lower pattern
Note) Enabled when [
Torque control] is set to “manual boost” only.
To avoid mechanical resonance, you
can specify a range where frequency
setting is disabled, or [
Jump
frequency width], from the frequency
specified by [
Jump frequency
①
] to [
Jump frequency
④
].
Jump frequency width
Jump frequency
①
Jump frequency
②
Jump frequency
③
Jump frequency
④
•
During acceleration/deceleration, frequency output is enabled even in
the jump range.
•
If jump frequency ranges are overlapped with each other, the entire
overlapped range is regarded as the jump range.
I1/I2 function
selection
Used to switch the command for the “I1” and “I2” input terminals as
follows:
■
(
:
Fwd-Stop
/
Rev-Stop
:
Run-Stop
/
Fwd-Rev)
■
: Factory setting
I1 – G
I2 – G
Input
terminal
Short-circuited
Open
Short-circuited
Open
CCW
Stop
CW
Stop
Run
Stop
CW
CCW
0
Output frequency
Ordinary V/F
O
utp
ut
vol
ta
g
e
2nd V/F
0
Output frequency
Upper
pattern
O
utp
ut
volta
g
e
0
Output frequency
Lower pattern
O
utp
ut
vo
lta
g
e
Frequency
①
Frequency
④
Frequency command (FIN - G)
Jump frequency
S
et
fr
equenc
y