[219]
Call Park Recall Time
Description
Sets the number of rings before call park recall occurs. Call park recall is used to alert an
extension that a call has been parked for an extended period of time.
Selection
Number of rings: 0 through 48 (0=Call Park Recall disabled)
Default
12 rings
Programming
1.
Enter 219.
Display: 219 PARK RECALL
2.
Press NEXT.
Display example: Time:12 rings
3.
Enter the number of rings.
To change the current entry, press CLEAR and enter the new number of rings.
4.
Press STORE.
5.
Press END.
Conditions
•
One ring is equivalent to five seconds.
•
Select "0" if Call Park Recall is not required.
•
You cannot leave the entry empty.
Features Guide References
Call Park
pg.book 99
ページ
2001年7月3日 火曜日 午後2時44分
Summary of Contents for KX-TA1232
Page 6: ...Table of Contents 6 Programming Guide pg book 6...
Page 19: ...General Programming Programming Guide 19 Section 2 General Programming pg book 19...
Page 30: ...General Programming 30 Programming Guide Operator pg book 30...
Page 57: ...General Programming Programming Guide 57 Features Guide References Caller ID pg book 57...
Page 73: ...General Programming Programming Guide 73 Call Log Incoming pg book 73...
Page 95: ...General Programming Programming Guide 95 Outgoing Message OGM Timed Reminder pg book 95...
Page 118: ...General Programming 118 Programming Guide Direct Inward System Access DISA pg book 118...
Page 151: ...General Programming Programming Guide 151 Features Guide References None pg book 151...
Page 155: ...General Programming Programming Guide 155 Paging Group Station Hunting pg book 155...
Page 167: ...General Programming Programming Guide 167 Features Guide References None pg book 167...
Page 202: ...General Programming 202 Programming Guide pg book 202...
Page 203: ...Default Values Programming Guide 203 Section 3 Default Values pg book 203...
Page 211: ...Index 211 Section 4 Index pg book 211...
Page 215: ...Index 215 pg book 215...