General Programming
70
Programming Guide
[124]
Phantom Extension Number Assignment
Description
Assigns the phantom extension numbers. Each number will be assigned to a flexible CO or
DSS (Direct Station Selection) button and used as a Phantom Extension button.
Selection
•
Location number: 001 through 128
•
Phantom extension number: 2 to 4 digits
Default
All locations — Not stored
Programming
1.
Enter 124.
Display: 124 PHANTOM #
2.
Press NEXT.
Display: Location NO?
3.
Enter a location number.
To enter location number 001, you can also press NEXT.
Display example: 001:Not Stored
4.
Enter a phantom number.
To delete the current entry, press CLEAR.
To change the current entry, press CLEAR and enter the new number.
5.
Press STORE.
6.
To program another location, press NEXT or PREV, or SELECT and the desired location
number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
•
Each phantom number has two to four digits, consisting of numbers 0 through 9.
•
The first one or two digits of the phantom extension numbers are subject to program
[100]
Flexible Numbering, (01) through (16) 1st through 16th hundred extension blocks.
•
Phantom extension numbers and other extension numbers should be unique. Double entry
and incompatible entry for these numbers are invalid. Valid entry example: 10 and 11, 10
and 110. Invalid entry example: 10 and 106.
To avoid making an invalid entry, check the other extension numbers in programs
pg.book 70
ページ
2001年7月3日 火曜日 午後2時44分
Summary of Contents for KX-TA1232
Page 6: ...Table of Contents 6 Programming Guide pg book 6...
Page 19: ...General Programming Programming Guide 19 Section 2 General Programming pg book 19...
Page 30: ...General Programming 30 Programming Guide Operator pg book 30...
Page 57: ...General Programming Programming Guide 57 Features Guide References Caller ID pg book 57...
Page 73: ...General Programming Programming Guide 73 Call Log Incoming pg book 73...
Page 95: ...General Programming Programming Guide 95 Outgoing Message OGM Timed Reminder pg book 95...
Page 118: ...General Programming 118 Programming Guide Direct Inward System Access DISA pg book 118...
Page 151: ...General Programming Programming Guide 151 Features Guide References None pg book 151...
Page 155: ...General Programming Programming Guide 155 Paging Group Station Hunting pg book 155...
Page 167: ...General Programming Programming Guide 167 Features Guide References None pg book 167...
Page 202: ...General Programming 202 Programming Guide pg book 202...
Page 203: ...Default Values Programming Guide 203 Section 3 Default Values pg book 203...
Page 211: ...Index 211 Section 4 Index pg book 211...
Page 215: ...Index 215 pg book 215...