General Programming
178
Programming Guide
[806]
Serial Interface (RS-232C) Parameters
Description
Assigns the communication parameters for the Serial Interface (RS-232C) interface.
New line code:
Select the code for your printer or personal computer. If your printer or personal computer
automatically feeds lines with a carriage return, select "CR". If not, select "CR+LF".
Baud rate:
A baud rate code indicates the data transmission speed from the system to the printer or
personal computer.
Word length:
A word length code indicates how many bits compose a character.
Parity:
A parity code indicates what type of parity is used to detect an error in the string of bits
composing a character. Make an appropriate selection depending on the requirements of your
printer or personal computer.
Stop bit:
A stop bit code indicates the end of a bit string which composes a character. Select an
appropriate value depending on the requirements of your printer or personal computer.
Selection
•
New line code: CR+LF / CR
(CR=Carriage Return, LF=Line Feed)
•
Baud rate (baud): 150 / 300 / 600 / 1200 / 2400 / 4800 / 9600 / 19200
•
Word length (bits): 7 / 8
•
Parity bit: None / Mark / Space / Even / Odd
•
Stop bit length (bits): 1 / 2
Default
New line code = CR+LF; Baud rate = 9600; Word length = 8;
Parity bit = Mark; Stop bit = 1
Programming
1.
Enter 806.
Display example: 806 RS232 PORT
2.
Press NEXT to program new line code.
Display example: NL-Code:CR+LF
3.
Keep pressing SELECT until the desired selection is displayed.
4.
Press STORE.
5.
Press NEXT to program baud rate.
Display example: Baud Rate:9600
pg.book 178
ページ
2001年7月3日 火曜日 午後2時44分
Summary of Contents for KX-TA1232
Page 6: ...Table of Contents 6 Programming Guide pg book 6...
Page 19: ...General Programming Programming Guide 19 Section 2 General Programming pg book 19...
Page 30: ...General Programming 30 Programming Guide Operator pg book 30...
Page 57: ...General Programming Programming Guide 57 Features Guide References Caller ID pg book 57...
Page 73: ...General Programming Programming Guide 73 Call Log Incoming pg book 73...
Page 95: ...General Programming Programming Guide 95 Outgoing Message OGM Timed Reminder pg book 95...
Page 118: ...General Programming 118 Programming Guide Direct Inward System Access DISA pg book 118...
Page 151: ...General Programming Programming Guide 151 Features Guide References None pg book 151...
Page 155: ...General Programming Programming Guide 155 Paging Group Station Hunting pg book 155...
Page 167: ...General Programming Programming Guide 167 Features Guide References None pg book 167...
Page 202: ...General Programming 202 Programming Guide pg book 202...
Page 203: ...Default Values Programming Guide 203 Section 3 Default Values pg book 203...
Page 211: ...Index 211 Section 4 Index pg book 211...
Page 215: ...Index 215 pg book 215...