5-68
Finisher tamper motor
Finisher staple motor
Code No.
Function
Check points
E7-22
E7-23
(1) Motor connector is shorted or broken.
(2) Motor is defective.
(3) Finisher controller PCB connector (CN-
J11) is shorted or broken.
(4) Finisher controller PCB is defective.
(5) (FP-D250/D350)
LVPS connector (
CN8
) is shorted or
broken.
(FP-D450/D600)
LVPS connector (
CN8
) is shorted or
broken.
(6) LVPS is defective.
(7) (FP-D250/D350)
CPU PCB connector (
CN15
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN15
) is shorted or
broken.
(8) CPU PCB is defective.
(1) Motor connector is shorted or broken.
(2) Motor is defective.
(3) Finisher controller PCB connector (CN-
J11) is shorted or broken.
(4) Finisher controller PCB is defective.
(5) Finisher relay PCB connector (CN-J301/
302/304) is shorted or broken.
(6) Finisher relay PCB is defective.
(7) (FP-D250/D350)
LVPS connector (
CN8
) is shorted or
broken.
(FP-D450/D600)
LVPS connector (
CN8
) is shorted or
broken.
(8) LVPS is defective.
(9) (FP-D250/D350)
CPU PCB connector (
CN15
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN15
) is shorted or
broken.
(10) CPU PCB is defective.