3-47
Preventive
Maintenance
Registration Adjustment
(1)Make a copy of Test Chart 53/54.
(2)For adjustment of lead edge registration
when making a copy off the platen glass,
use
F6-05
.
(To advance the registration, input a more
(+) number)
(3)For adjustment of lead edge registration
when making a copy using the FA-A888,
use
F6-36
and
37
to achieve proper
registration.
(To delay the registration, input a more (–)
number)
(4)For adjustment of lead edge registration,
when making a copy using the FA-A355,
use
F6-91
.
(+/–) = delay / advance
Location
Procedure
Location
Procedure
(1)Make a copy of Test Chart 53/54.
(2)Adjust the lead edge void using
F6-07
.
(+) = more void
(–) = less void
(3)Adjust the trail edge void by using
F6-09
.
(+) = less void
(–) = more void
5. Lead edge / Trail edge void adjustment (Printer Section)