Chapter 4
Settings — [PROJECTOR SETUP] menu
ENGLISH - 95
[ECO MANAGEMENT]
Set the operation method of the projector.
Setting [OPERATING MODE]
1) Press
as
to select [ECO MANAGEMENT].
2) Press the <ENTER> button.
f
The
[ECO MANAGEMENT]
screen is displayed.
3) Press
as
to select [OPERATING MODE].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[NORMAL]
Set this item when high luminance is required. [LIGHT OUTPUT] is 100 %, and the estimated runtime
is approximately 20 000 hours
*1
.
[ECO]
Set this item to increase the life of the light source, though it will lower the luminance than [NORMAL].
[LIGHT OUTPUT] is 80 %, and the estimated runtime is approximately 24 000 hours
*1
.
[QUIET]
Select this item when operation with lower noise is preferred. [LIGHT OUTPUT] is 80 %, and the
estimated runtime is approximately 20 000 hours
*1
.
[USER]
[LIGHT OUTPUT] can be set individually.
*1 Estimated runtime is the time until the brightness decreases to approximately half of the time of delivery when the projector is used with the
[PICTURE] menu → [DYNAMIC CONTRAST] set to [2] and under environment of 0.15 mg/m
3
dust. The value of runtime is just an estimate,
and is not the warranty period.
f
Proceed to Step
5)
when [USER] is selected.
5) Press
as
to select [LIGHT OUTPUT].
6) Press
qw
to adjust.
Operation
Adjustment
Range of adjustment
Brightness
Runtime (estimate)
Press
w
.
The screen becomes brighter.
The runtime becomes shorter.
20 % - 100 %
Press
q
.
The screen becomes darker.
The runtime becomes longer.
Note
f
When [USER] is selected, the uniformity of brightness between multiple screens can be maintained by adjusting [LIGHT OUTPUT] of each
projector when a multi-display screen is structure with multiple projectors.
f
If the runtime exceeds 20 000 hours, replacement of the components inside the projector may be required. Consult your dealer for details.
Interrelation of brightness and runtime
The projector can be operated at arbitrary brightness and duration of use by combining the settings of [LIGHT
OUTPUT], and [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP].
Interrelation of brightness and runtime is as follows. Make the settings depending on your desired duration of use
and brightness of the projected image.
Values of the brightness and runtime are rough estimations.
f
When [CONSTANT MODE] is set to [OFF]
[LIGHT OUTPUT] (%)
PT-FRZ60
PT-FRZ50
Brightness (lm)
Estimated runtime
* 1
(hour)
Brightness (lm)
Estimated runtime
*1
(hour)
100.0
6 000
20 000
5 200
20 000
69.5
4 200
24 000
3 600
24 000
29.0
1 700
27 000
1 500
27 000
*1 Estimated runtime is the time until the brightness decreases to approximately half of the time of delivery when the projector is used with the [PICTURE]
menu → [DYNAMIC CONTRAST] set to [2] and under environment of 0.15 mg/m
3
dust.
Summary of Contents for DLP PT-FRZ50
Page 38: ...38 ENGLISH Chapter 3 Basic Operations This chapter describes basic operations to start with ...
Page 130: ...130 ENGLISH Chapter 5 Operations This chapter describes how to use each function ...
Page 188: ...Index 188 ENGLISH WAVEFORM MONITOR 92 Web control 134 WHITE GAIN 65 WIRED LAN 122 Z ZOOM 70 ...