Chapter 4
Settings — [PROJECTOR SETUP] menu
96 - ENGLISH
f
When [CONSTANT MODE] is set to [AUTO] or [PC]
[LIGHT OUTPUT] (%)
PT-FRZ60
PT-FRZ50
Brightness (lm)
Estimated runtime
*1
(hour)
Brightness (lm)
Estimated runtime
*1
(hour)
50.0
3 000
20 000
2 600
20 000
41.1
2 500
24 000
2 100
24 000
35.0
2 100
27 000
1 800
27 000
27.4
1 600
31 000
1 400
31 000
20.7
1 200
35 000
1 100
35 000
13.3
800
40 000
700
40 000
*1 Estimated runtime is the time the brightness is maintained constant when the projector is used with the [PICTURE] menu → [DYNAMIC
CONTRAST] set to [2] and under environment of 0.15 mg/m
3
dust. The brightness will gradually decrease after exceeding this time.
Note
f
Under influences of characteristics of each light source, conditions of use, installation environment, etc., the runtime may be shorter than the
estimation.
f
If the runtime exceeds 20 000 hours, replacement of the components inside the projector may be required. Consult your dealer for details.
Setting [AUTO POWER SAVE]
Enable/disable the [AMBIENT LIGHT DETECTION] and [NO SIGNAL LIGHTS-OUT] functions.
1) Press
as
to select [ECO MANAGEMENT].
2) Press the <ENTER> button.
f
The
[ECO MANAGEMENT]
screen is displayed.
3) Press
as
to select [AUTO POWER SAVE].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Disables the auto power save setting.
[ON]
Enables the auto power save setting.
5) Press
as
to select [AMBIENT LIGHT DETECTION] or [NO SIGNAL LIGHTS-OUT].
[AMBIENT LIGHT
DETECTION]
Adjusts the power of the light source in accordance with the brightness of the installed location.
[NO SIGNAL LIGHTS-OUT]
Automatically turns off the light source of the projector when there is no input signal for specific
period.
6) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[AMBIENT LIGHT
DETECTION]
[OFF]
Disables the ambient light detection function.
[ON]
Enables the ambient light detection function.
[NO SIGNAL LIGHTS-OUT]
[DISABLE]
Disables the no signal lights-out function.
[10SEC.] - [5MIN.]
Turns off the light source when there is no input signal for the preset
period.
Select [10SEC.], [20SEC.], [30SEC.], [1MIN.], [2MIN.], [3MIN.], or
[5MIN.].
Note
f
[AMBIENT LIGHT DETECTION] and [NO SIGNAL LIGHTS-OUT] cannot be set when [AUTO POWER SAVE] is set to [OFF].
f
The power indicator <ON (G)/STANDBY (R)> will blink green slowly while the no signal lights-out function is operating and the light source is
turned off.
f
When [NO SIGNAL LIGHTS-OUT] is set to anything other than [DISABLE], the conditions to turn on the light source again from the condition
that the light source was turned off by this function are as follows.
g
When the signal has been input
g
When on-screen display such as menu screen (OSD) or input guide, a test pattern, or a warning message is displayed
g
When the power <
v
/
b
> button is pressed
g
When the operation to disable the shutter function (shutter: open) is performed, such as pressing the <SHUTTER> button
g
When the operating environment temperature is around 0 °C (32 °F) and the light source is forced to turn on due to warm-up
f
The luminance may not be detected correctly when an object is placed on top of the projector, blocking the luminance sensor. In such a
case, it may not operate properly even if [AMBIENT LIGHT DETECTION] is set to [ON].