Chapter 4 Operation — Menu settings
The items that can be set are as follows.
f
[SLOT2], [SLOT3]
(Factory setting: [SLOT2])
[BATTERY]
[DC IN SOURCE]
Sets the type of external power supply to input to the <DC IN> terminal.
The items that can be set are as follows.
[DC POWER SUPPLY]
Select when connecting the AC adaptor.
[BATTERY]
Select when connecting the battery.
Voltage to display full/near end/end remaining capacity can be set in the [OTHERS] menu
→
[BATTERY]
→
[DC IN
BATTERY].
(Factory setting: [DC POWER SUPPLY])
[DC IN BATTERY]
[FULL VOLT]
Sets the voltage to display full remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f
[13.0V] … [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
[NEAR END VOLT]
Sets the voltage to display near end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f
[11.1V] … [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
[END VOLT]
Sets the voltage to display end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f
[11.0V] … [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
[ONBOARD BATTERY]
[BATTERY SEL]
Select according to the used battery.
When set to [DIONIC], [HYTRON/TITON], [ENDURA], or [PAG], remaining capacity is detected and the warning is displayed
according to the [NEAR END INFO] or the [END INFO] setting.
The remaining capacity is detected by the voltage level when set to [other].
When there is no remaining capacity information, the remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f
[DIONIC], [HYTRON/TITON], [ENDURA], [PAG], [other]
(Factory setting: [DIONIC])
[FULL VOLT]
Sets the voltage to display full remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f
[13.0V] … [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
[NEAR END VOLT]
Sets the voltage to display near end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f
[11.1V] … [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
[END VOLT]
Sets the voltage to display end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f
[11.0V] … [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
[NEAR END INFO]
Sets the percent value of the near end remaining capacity when the remaining capacity information is acquired from the
battery.
The items that can be set are as follows.
f
[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
(Factory setting: [5%])
[END INFO]
Sets the percent value of the end remaining capacity when the remaining capacity information is acquired from the battery.
The items that can be set are as follows.
f
[1%] … [10%] (1% steps)
(Factory setting: [1%])
[GENLOCK]
[GENLOCK]
Switches the synchronization signal of the camera.
[INT]
Synchronizes to the internal standard signal regardless of the standard signal input to the <GENLOCK IN> terminal.
[GL IN]
Synchronizes to the standard signal input to the <GENLOCK IN> terminal.
(Factory setting: [INT])
[H PHASE COARSE]
Performs coarse adjustment to match horizontal synchronization phase when building a system.
Summary of Contents for AJ-CX4000G
Page 12: ...Before using the camera read this chapter Chapter 1 Overview ...
Page 177: ...This chapter describes about the output image Chapter 7 Output ...
Page 202: ...Maintenance of the camera and error message are described Chapter 10 Maintenance ...
Page 221: ...Web Site https www panasonic com Panasonic Corporation 2019 ...