1 Introduction
-
5
-
EMC Directive
Provide EMC measures when installing/wiring the product. Without effective measures to suppress EMI
(electromagnetic interference) caused by the motorized actuator, controller or teaching pendant in the
surrounding control systems equipment and to address EMS (electromagnetic susceptibility) of the motorized
actuator, controller or teaching pendant, the machine’s performance may be severely affected.
This product has received EMC measures under the conditions specified in “Example of installation and
wiring” on p.10.
Be sure to measure EMC (electromagnetic compatibility) with the product in your equipment, by referring to
2.3, “Installing and wiring in compliance with EMC directives” on p.9.
Applicable standards
ESMC-K ESMC-A
,
ESMC-C
EMI Emission
Tests
Radiated Emission Test
Conducted Emission Test
EN 61000-6-4
EN 55011
−
EN 61000-6-4
EN 55011
EN 55011
EMS Immunity
Tests
Electrostatic Discharge Immunity Test
Radiation Field Immunity Test
Fast transient/Burst Immunity Test
Surge Immunity Test
Conductive Noise Immunity test
Voltage Dip Immunity Test
Voltage Interruption Immunity Test
EN 61000-6-2
IEC 61000-4-2
∗
IEC 61000-4-3
IEC 61000-4-4
−
IEC 61000-4-6
−
−
EN 61000-6-2
IEC 61000-4-2
∗
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-11
IEC 61000-4-11
∗
Teaching pendant: 10 kV both in air and in the contact state
Machinery Directive
The motorized actuators and controllers are designed and manufactured for use as an internal component for
general industrial equipment, and therefore need not comply with the Machinery Directive.
Nonetheless, they are evaluated under the following standards:
Applicable standards: EN ISO 12100-1, EN ISO 12100-2, EN 1050, EN 60204-1