40
■
Driver Dimensions
(Unit = mm)
●
Built-In Controller Type
Driver Product Name:
LRD503-KD
,
LRD507-KD
,
LRD514-KD
Mass: 0.2 kg
100
4.7
35
70
5.5
17.5
35.1
37 m
a
x.
20 m
a
x.
9.2 m
a
x.
●
Included
Power Connector (CN1)
Connector: MC1,5/3-STF-3,5 (Phoenix Contact)
Connection Cable (for I/O signals) (CN2, length 1 m)
Connector: FX2B-40SA-1.27R (Hirose Electric)
Connection Cable (for actuator connector) (CN4, length: 0.6 m)
Connector Housing: 51103-0500 (Molex)
Contact: 50351-8100 (Molex)
Applicable Crimp Tool: 57295-5000 (Molex)
◇
Connection Cable (for I/O signals, CN2)
19
7
30
+
100
1000
0
Connector
◇
Connection Cable (for actuator connector, CN4)
5
1
9.5
14.7
600
±
5
●
Pulse Input Type
Driver Product Name:
LRD503-K
,
LRD507-K
,
LRD514-K
Mass: 0.12 kg
35
100
17.5
4.7
35.1
5.5
70
17 m
a
x.
9.2 m
a
x.
●
Included
Power Connector (CN1)
Connector: MC1,5/3-STF-3,5 (Phoenix Contact)
Actuator Connector (CN2)
Connector: MC1,5/5-STF-3,5 (Phoenix Contact)
I/O Signal Connector (CN3)
Connector: FK-MC0,5/10-ST-2,5 (Phoenix Contact)
■
Built-In Controller Type RS-485 Communication Specification
Protocol
Modbus protocol (Modbus RTU mode)
Electrical
Characteristics
EIA-485 based, straight cable
Use twisted-pair wire (TIA/EIA-568B CAT5e or higher is recommended), and set a max. total length of 50 m.
Communication
Mode
Half-duplex communication, start-stop synchronization method (Data: 8 bits, stop bit: 1 bit/2 bits, parity: none/even numbers/odd
numbers)
Baud Rate
9600 bps/19200 bps/38400 bps/57600 bps/115200 bps
Connection Type
Up to 31 can be connected to each programmable controller (master equipment).