7 - 35
7 Ethernet/IP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
7-
2 V780 Co
mm
and
Detail
s
7
7-2
-5 Rea
der/W
riter Setting Comman
ds: D
evice Setting
s
z
Function
This command is used to check the Multi-Reader/Writer configuration set in the Multi-Reader/Writer.
z
Command Area
z
Response Area
GET MUTLI-READER/WRITER CONFIGURATION
Signal/data
Data type
Size
Function
CmdCode/Command Code
WORD
2 bytes
5004 hex
CmdParam1/Command Parameter 1
WORD
2 bytes
0000 hex (Not used.)
CmdParam2/Command Parameter 2
WORD
2 bytes
0000 hex (Not used.)
Reserved/Reserved Area
WORD
2 bytes
0000 hex (Not used.)
Cnt Response/Update Counter
Response
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to
Signal/data
Data type
Size
Function
ErrCode/Error Code
WORD
2 bytes
Error code
RespInfo1/Response Information 1
WORD
2 bytes
0000 hex (Not used.)
RespInfo2/Response Information 2
WORD
2 bytes
0000 hex (Not used.)
RespInfo3/Response Information 3
WORD
2 bytes
0000 hex (Not used.)
Cnt/Update Counter
WORD
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to
RespData/Response Data
Multi-Reader/Writer Mode
WORD
2 bytes
Expresses whether the multi-Reader/Writer
Mode is enabled or disabled.
0000 hex: Disable
0001 hex: Enable
Default setting: 0000 hex
Number of Slave Reader/Writ-
ers
WORD
2 bytes
Expresses the number of Slave Readers/Writers.
0000 to 0007 hex
Default setting: 0000 hex
Slave Reader/Writer 1
DWORD
4 bytes
Expresses the IP address of Slave
Reader/Writer 1.
Example) C0A801C9 (192.168.1.201)
Default setting: 00000000 hex
Slave Reader/Writer 2
DWORD
4 bytes
Expresses the IP address of Slave
Reader/Writer 2.
Example) C0A801CA (192.168.1.202)
Default setting: 00000000 hex
...
...
...
...
Slave Reader/Writer 6
DWORD
4 bytes
Expresses the IP address of Slave
Reader/Writer 6.
Example) C0A801CE (192.168.1.206)
Default setting: 00000000 hex
Slave Reader/Writer 7
DWORD
4 bytes
Expresses the IP address of Slave
Reader/Writer 7.
Example) C0A801CF (192.168.1.207)
Default setting: 00000000 hex