Installation
This section describes the installation of the Reader/Writer and RF Tags.
The Reader/Writer can be installed from the front or the rear.
z
Front Mounting
Install the Reader/Writer with four M6 bolts. Use both spring washers and flat washers.
(Unit: mm)
z
Rear Mounting
Install the Reader/Writer with four M6 bolts. Use both spring washers and flat washers.
(Unit: mm)
Precautions for Correct Use
• An M6 bolt engagement length of 6 to 8 mm is necessary for rear mounting.
• The bolts may be hard to tighten. Tighten them to the recommended tightening torque.
• When you install the Reader/Writer, observe the tightening torque (4.3 N·m) for the M6 bolts.
4-1-1
Reader/Writer
V780-HMD68-EIP-
Spring washer
Flat washer
M6 bolt
230±0.3
Four, M6 holes
230±0.3
Mounting Hole Dimensions
Spring washer
Flat washer
M6 bolt
75±0.2
Four,
6.6-dia. holes
75±0.2
Mounting Hole Dimensions