7 Ethernet/IP Communications
7 - 28
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
z
Function
This command restarts the entire Reader/Writer.
z
Command Area
z
Response Area
RESET
Signal/data
Data type
Size
Function
CmdCode/Command Code
WORD
2 bytes
1002 hex
CmdParam1/Command Parameter 1
WORD
2 bytes
Options
0000 hex: Reboot (Normal start)
0001 hex: Reboot (Safe Mode start)
FFFE hex: Forced reset (SAFE Mode start)
FFFF hex: Forced reset (Normal start)
Reboot: Reset is performed after the
Reader/Writer is set to an idle state.
Forced reset: Reset is performed immediately
when the command is received, without waiting
for the Reader/Writer to be set to an idle state.
CmdParam2/Command Parameter 2
WORD
2 bytes
0000 hex (Not used.)
Reserved/Reserved Area
WORD
2 bytes
0000 hex (Not used.)
Cnt Response/Update Counter
Response
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to
Signal/data
Data type
Size
Function
ErrCode/Command Code
WORD
2 bytes
Error code
RespInfo1/Response Information 1
WORD
2 bytes
0000 hex (Not used.)
RespInfo2/Response Information 2
WORD
2 bytes
0000 hex (Not used.)
RespInfo3/Response Information 3
WORD
2 bytes
0000 hex (Not used.)
Cnt/Update Counter
WORD
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to
Note In the case of a forced reset, restart is performed without any output in the response area. During a
reboot, an output is performed in the response area.