9 - 17
9 Troubleshooting
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
9-3 Errors a
nd C
o
u
n
term
easures
9
9-3-
4 Major F
ault
9-3-4
Major Fault
Error name
System configuration error
Error code
F00* hex
Description
A mistake was detected in the system program or system data stored in memory in the
Reader/Writer.
Detection timing
At startup
Recovery method
Reboot.
Log category
System error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
Memory inside the Reader/Writer is faulty.
Workaround
If this error continues to occur even if you restart the Reader/Writer, replace the Reader/Writer.
Precautions/
Remarks
If this error is detected, the Reader/Writer will start in Safe Mode.
Error name
Non-volatile memory access error
Error code
F01* hex
Description
Reading/writing non-volatile memory in the Reader/Writer failed.
Detection timing
At change to settings
Recovery method
Reboot.
Log category
System error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
Memory inside the Reader/Writer is faulty.
Workaround
If this occurs continues to occur even if you restart the Reader/Writer, replace the Reader/Writer.
Precautions/
Remarks
Error name
Hardware fault
Error code
F02* hex
Description
A failure was detected in the hardware in the Reader/Writer.
Detection timing
At RF communications execution
Recovery method
Reboot.
Log category
System error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
The IC or antenna in the Reader/Writer is faulty.
Workaround
If this occurs continues to occur even if you restart the Reader/Writer, replace the Reader/Writer.
Precautions/
Remarks
9-3-5
WDT Error
Error name
WDT error
Error code
None
Description
A watchdog timer timeout that resulted from CPU runaway in the Reader/Writer was detected.
Detection timing
During operation
Recovery method
Reboot.
Log category
None
Probable cause
A hardware failure or temporary data corruption caused the CPU runaway.
Workaround
If this occurs continues to occur even if you restart the Reader/Writer, replace the Reader/Writer.
Precautions/
Remarks
A WDT error is not recorded in the command error log or system error log.
Summary of Contents for V780-HMD68-EIP-JP
Page 152: ...6 Functions 6 80 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Page 321: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 Index ...
Page 324: ...I 4 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 Index ...
Page 325: ......