6 - 31
6 Functions
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
6-4 R
eader/W
riter Sett
ing
s
6
6-
4-4 De
vice
S
e
ttings
You can change the NORM/ERR indicator lighting pattern after Reader/Writer command execution.
You can set one of eight lighting patterns: Lit in each of seven colors and OFF.
You can change only the NORM/ERR indicator lighting pattern that appears after command execu-
tion. You cannot change the lighting pattern for minor and major faults (lit red).
Precautions for Correct Use
The custom indicator settings are not used during test operation for tuning or utility functions
performed from the Web browser interface. The indicators will light in the default colors.
6-4-4
Device Settings
Operation Indicator Custom Settings
Setting item
Description
Default
Command normal
(NORM)
The indicators light with the specified lighting pattern when
processing a communications command or another com-
mand from the host device is completed normally.
Lights green
Command error
(ERROR)
The indicators light with the specified lighting pattern when
processing a communications command or another com-
mand from the host device ends in an error.
Lights red
Unstable communi-
cations (WARNING)
The indicators light with the specified lighting pattern each
time an unstable communication is detected while commu-
nications diagnosis is enabled.
Lights yellow
R: Red
G: Green
B: Blue
Y: Yellow
C: Cyan
M: Magenta
W: White
R
G
B
M
Y
C
W
NORM/ERR
NORM/ERR
NORM/ERR
NORM/ERR