7 Ethernet/IP Communications
7 - 44
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
z
Function
This command sets the channels for the Reader/Writer.
z
Command Area
z
Response Area
SET CHANNEL
Signal/data
Data type
Size
Function
CmdCode/Command Code
WORD
2 bytes
3005 hex
CmdParam1/Command Parameter 1
WORD
2 bytes
0000 hex (Not used.)
CmdParam2/Command Parameter 2
WORD
2 bytes
0000 hex (Not used.)
Reserved/Reserved Area
WORD
2 bytes
0000 hex (Not used.)
Cnt Response/Update Counter
Response
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to
CmdData/Command Data
Channel
WORD
2 bytes
Specifies the channel.
*1
[For JP]
0000 hex: Auto
0005 hex: 5 CH
000B hex: 11 CH
0011 hex: 17 CH
*1. You can set the channels to use only in the models for JP. You cannot set the channels for any other model.
Signal/data
Data type
Size
Function
ErrCode/Command Code
WORD
2 bytes
Error code
RespInfo1/Response Information 1
WORD
2 bytes
0000 hex (Not used.)
RespInfo2/Response Information 2
WORD
2 bytes
0000 hex (Not used.)
RespInfo3/Response Information 3
WORD
2 bytes
0000 hex (Not used.)
Cnt/Update Counter
WORD
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to