9 - 9
9 Troubleshooting
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
9-3 Errors a
nd C
o
u
n
term
easures
9
9-3-
1 Comman
d Error
s
*1. This provides information on the current minor fault.
Error name
Command execution failure, busy
Error code
1011 hex
Description
The Reader/Writer was executing another command and could not execute the received com-
mand.
Detection timing
At command execution
Recovery method
None
Log category
Command error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
(1) An RF communications command was received during a setting change.
(2) A setting command was received during execution of an RF communications command.
Workaround
Check the operation status of the Reader/Writer and send the command again.
Precautions/
Remarks
None
Error name
Command execution failure (inappro-
priate operation mode)
Error code
1012 hex
Description
The received command cannot be executed in the current operation mode of the Reader/Writer.
Detection timing
At command execution
Recovery method
None
Log category
Command error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
An RF communications command was received during operation in Safe Mode.
Workaround
Check the operation mode of the Reader/Writer and send the command again.
Precautions/
Remarks
None
Error name
Command execution failure (inappro-
priate RF communications mode)
Error code
1013 hex
Description
The received command cannot be executed in the current RF communications mode of the
Reader/Writer.
Detection timing
At command execution
Recovery method
None
Log category
Command error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
A multiaccess RF communications command was received in Focus Mode.
Workaround
Check the RF communications mode of the Reader/Writer and send the command again.
Precautions/
Remarks
None
Error name
Command execution failure, minor
fault
Error code
1018 hex
Description
There was a system error (minor fault) in the Reader/Writer and the Reader/Writer could not exe-
cute the received command.
Detection timing
At command execution
Recovery method
Restart the Reader/Writer.
Log category
Command error log
Additional infor-
mation 1
Error code*
Additional infor-
mation 2
None
Probable cause
Refer to the error information for a minor fault in additional information 1.
Workaround
Precautions/
Remarks
None