7 Ethernet/IP Communications
7 - 32
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
z
Function
This command is used to set or clear a name for the Reader/Writer.
z
Command Area
z
Response Area
SET DEVICE NAME
Signal/data
Data type
Size
Function
CmdCode/Command Code
WORD
2 bytes
200B hex
CmdParam1/Command Parameter 1
WORD
2 bytes
0000 hex (Not used.)
CmdParam2/Command Parameter 2
WORD
2 bytes
0000 hex (Not used.)
Reserved/Reserved Area
WORD
2 bytes
0000 hex (Not used.)
Cnt Response/Update Counter
Response
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to
CmdData/Command Data
Device name
ARRAY[]
OF BYTE
64 bytes
ASCII characters
*1
, 64 bytes max.
(Filled with up to 63 ASCII characters plus the
end code (00 hex))
Specify 00 hex for all bytes to clear the device
name.
Default setting: 00 hex for all bytes
*1. The device name is given with ASCII characters 20 hex (space) to 7E hex (~).
Signal/data
Data type
Size
Function
ErrCode/Command Code
WORD
2 bytes
Error code
RespInfo1/Response Information 1
WORD
2 bytes
0000 hex (Not used.)
RespInfo2/Response Information 2
WORD
2 bytes
0000 hex (Not used.)
RespInfo3/Response Information 3
WORD
2 bytes
0000 hex (Not used.)
Cnt/Update Counter
WORD
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to