9 Troubleshooting
9 - 12
UHF RFID System V780-series Reader/Writer User’s Manual (EtherNet/IP
TM
) (Z402)
*1. When the environment is unstable, this error can occur even if the access password is correct.
Error name
RF Tag verification error
Error code
2006 hex
Description
Verification was performed for the results of writing data to the RF Tag, but inconsistencies were
discovered.
Detection timing
At RF communications execution
Recovery method
None
Log category
Command error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
(1) There is no RF Tag in the stable communications range of the RF Tag.
(2) The ambient environment is affecting operation (radio wave interference or surrounding metal).
(3) Collision occurred for responses from more than one RF Tag.
Workaround
Execute the command again. If the same error still occurs, try the following measures.
Make sure there is an RF Tag in the stable communications range.
Adjust the execution timing of the command to start communications with the RF Tag.
Precautions/
Remarks
Error name
RF Tag system error
Error code
2008 hex
Description
The RF Tag returned an error response.
Detection timing
At RF communications execution
Recovery method
None
Log category
Command error log
Additional infor-
mation 1
Manufacturer analysis code
Additional infor-
mation 2
Manufacturer analysis code
Probable cause
(1) The RF Tag does not support the RF communications protocol of the Reader/Writer
(ISO-18000-6C (Gen2)).
(2) The RF Tag is faulty.
Log category
Workaround
Consult with your OMRON representative concerning RF Tags that can communicate with the
Reader/Writer.
Replace the RF Tags with RF Tags that can communicate with the Reader/Writer.
Precautions/
Remarks
Error name
Password error
Error code
2009 hex
Description
The access password does not match the RF Tag.*
Detection timing
At RF communications execution
Recovery method
None
Log category
Command error log
Additional infor-
mation 1
None
Additional infor-
mation 2
None
Probable cause
The access code in the RF Tag and the access code set in the Reader/Writer do not agree.
Workaround
Check the access password set in the RF Tag.
Precautions/
Remarks
Summary of Contents for V780-HMD68-EIP-JP