![background image](http://html1.mh-extra.com/html/omron/v690-series/v690-series_user-manual_741403084.webp)
5-7 Tag Communication Command
5-28
<Response Format> * A figure below shows the number of characters.
<Poling Response Format> * A figure below shows the number of characters.
Response immediately after a polling command is issued.
DA
Destination (host device) station number. * In the command format, the destination is an
antenna.
SA
Source (antenna) station number.
Termination code
"00": For a normal end. For any other termination codes, refer to "5-10 Termination Code
List".
Response number
Fixed to "01".
ID code
ID code of tag. This is inherent to tag and cannot be rewritten.
Termination code
Fixed to "00".
Correct Usage
For an available range of number of written bytes, check the ID tag memory capacity.
Command
code
Termination
code
Response
number
ID code
(BCC)
* It can be specified whether BCC is enabled or disabled.
Command
code
Termination
code
(BCC)
* It can be specified whether BCC is enabled or disabled.