5-7 Tag Communication Command
5-25
5-7-5 Tag Designation Write
Writes a data into a particular ID tag.
<Command Format> * A figure below shows the number of characters.
Start address, number of read bytes
DA
Destination (antenna) station number. "00" to "31". This can
be modified in "5-9-8 Station Number Setting".
Initial value "00"
SA
Source (host device) station number. "80" to "89". If only one host device is used, specify "80".
Command code
W1: Single Trigger, with verification read. * For the verification, refer to Section 5-7-4.
W3: Single Trigger, without verification read.
Communication designa-
tion
Gives communication designation to a tag.
SN: A tag will be in a sleep state after execution.
WN: A tag will be in a standby state after execution.
ID code
Specify an ID code of a particular tag.
Split flag
Specify "A".
Code designation
Specify whether data read out of a tag is ASCII code or hexadecimal code.
A: ASCII code
H: Hexadecimal code
Start address
Specify according to the table below.
Number of written bytes
Written content
Start address
Number of written bytes
ASCII code
Hexadecimal code
Data
Reading start
address
("0000" to "1FFF")
* Hexadecimal number
Specify the number of written
bytes
("0001" to "2000")
* Hexadecimal number
Specify the number of written
bytes
("0001" to "1000")
* Hexadecimal number
Write Protect setting
"WPRO"
Unavailable
"0004" * Refer to Section 3-6.
Waiting time for sleep
"SLEP"
"0004" * Refer to Section 3-7.
Split flag
Command
code
Code designation
Start address
Number of
written bytes
(BCC)
* It can be specified whether BCC
is enabled or disabled.
Commu-
nication
designation
ID code
Written data
Specified number