4-3 Link Unit
4-18
♦
♦
♦
♦
Connecting power supply wire, grounding wire and signal wire
M3 screws are used for the power supply, grounding and signal terminals. For a crimp terminal, use any of terminals below. Tightening
torque is 0.6 N•m (approximately 6 kgf•cm).
••••
Applicable crimp terminal
••••
Recommendable 24 VDC power supply
Model S82K-01524 (Output: 24 VDC, 0.6 A. Input: 100 to 240 VAC. OMRON)
••••
Be sure to ground GR according to the Class D.
Manufacturer
Model
Applicable Wire
Type
Japan Solderless Terminal
1.25-B3A
AWG22 to
AWG16
Fork
Japan Solderless Terminal
1.25-C3A
Correct Usage
If any noise superposed on the power supply line is large, supply the power through a line filter. Then, ground noise can
be reduced considerably. Example of line filter: Model GT-205J (Tokin).
(Example of connection)
Grounding according to Class D
(For M3)