![background image](http://html1.mh-extra.com/html/omron/v690-series/v690-series_user-manual_741403069.webp)
5-4 Communication and Communication Designation List
5-13
(3) Antenna setting command
Note 1. To enable "Host Communication Condition Setting" and "Station Number Setting", you must issue a reset command (Section
5-8-2) or reset the power supply after issuing a command.
Note 2. 9.6 kbps, data length 7 bits, even parity, stop bit 2, no BCC. (Refer to Section 5-9-7)
Command name
(Referred item)
Operation
mode
Setting
mode
After resetting power
supply or executing reset
Function
Initial
value
Radio Wave Transmis-
sion ON (Section 5-9-1)
A0
Enabled
Disabled
No change in the radio
wave OFF mode.
Selects the radio wave transmis-
sion OFF mode.
OFF
mode
Radio Wave Transmission
OFF (Section 5-9-1)
A1
Returns to the radio
wave OFF mode.
Selects the radio wave ON mode.
Communication Range
Selection (Section 5-9-2)
A4
Enabled
Setting before
resetting does
not change.
Selects the range selection mode
(2 m/5 m).
2 m
mode
Radio Wave Channel
Selection (Section 5-9-2)
A5
Selects a radio wave channel (0 -
9).
5
(2450 MHz)
Radio Wave Output Sta-
tus Read (Section 5-9-3)
A6
Reads a communication range
mode and radio wave channel.
Setting of Time to Wait
Tag (Section 5-9-4)
T4
Sets a waiting time for communication with
a tag after command execution when exe-
cuting Auto or Repeat command.
Unlimited
Command Data
Response Time Setting
(Section 5-9-5)
H4
Sets a command response time,
data response time intervals.
10 ms
10 ms
Read Data Length Set-
ting
(Section 5-9-6)
H3
Sets maximum data length which
can be returned by one response of
data read command.
256 bytes
Host Communication
Condition Setting
(Section 5-9-7)
H5
Enabled (Note 1)
Sets conditions of communication
with a host device.
27E200
(Note 2)
Station Number Setting
(Section 5-9-8)
H6
Sets an antenna station number.
00
Setting Read
(Section 5-9-9)
M2
Disabled
Reads an antenna setting value.